| CN1A 25 PB00 |
25 |
±36 |
±15 |
±25mA |
±0.5 |
150 |
-40~85 |
NA |
+ |
|
- Closed loop (compensated) current sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion loss
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
- Industrial Hall effect current sensors for UPS
more...
|
| AT4V 200 H00 |
200 |
±600 |
±12...15 |
±4V |
±1.0 |
50 |
-40~105 |
10 x 12mm(Three holes) |
|
HX PZ2.54-1X6P WZ |
- Three-phase open loop current sensor using the Hall effect
- Operating temperature range:-40℃~ 105℃
- Insulating plastic case recognized according to UL 94-V0
- Voltage ratio output
- Very good linearity
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
more...
|
| CN2A 40 PB01 |
40 |
±110 |
±12...15 |
±20mA |
±0.5 |
200 |
-40~85 |
NA |
+ |
|
- Closed loop (compensated) current sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion loss
- Standards:
- IEC 60664-1:2020 IEC 61800-5-1:2022 IEC 62109-1:2010
- Premium made in China DC hall effect current tranducer
more...
|
| CS3A 50 P01 |
50 |
±90 |
±12...15 |
±50...90mA |
±0.3 |
200 |
-40~85 |
13.5 x 10 mm |
+ |
|
- Closed loop (compensated) current sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion loss
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
- High quality good linearity PCB mount type current sensor
more...
|
| CS3A 50 P51 |
50 |
±90 |
±12...15 |
±50...90mA |
±0.3 |
150 |
-20~75 |
13.5 x 10 mm |
+ |
|
- Closed loop (compensated) current sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion loss
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
- Closed loop Hall effect AC/DC current sensor power supply±12V ~ ±15V
more...
|
| CN2A 50 PB01 |
50 |
±110 |
±12...15 |
±25mA |
±0.5 |
200 |
-40~85 |
NA |
+ |
|
- Closed loop (compensated) current sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion loss
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
- Measurement:Current Nominal Value:50A
- Measuring Range:110A
- Supply voltage range:12-15V
- Accuracy:0.5%
- Technology:Closed loop Hall effect
- Mounting:PCB
Measurement current 50A supply voltage :12V-15V closed loop hall effect PCB mounting
more...
|
| CN2A 80 PB01 |
80 |
±160 |
±12...15 |
±40mA |
±0.5 |
200 |
-40~85 |
NA |
+ |
|
- Closed loop (compensated) current sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion loss
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
- Closed-loop current sensors high-precision measurement for industries such as manufacturing, energy and rail transit.
more...
|
| CN2A 100 PB01 |
100 |
±160 |
±12...15 |
±50mA |
±0.5 |
200 |
-40~85 |
NA |
+ |
|
- Closed loop (compensated) current sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion loss
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
- A Hall current sensor measures electrical current for electric vehicles and industrial machines.
more...
|
| CR1A 100 H00 |
100 |
±200 |
±12...15 |
±50...100mA |
±0.5 |
200 |
-40~85 |
Ø23 |
|
MOLEX 5045-04A |
- Closed loop(compensated)current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion losses
- Standards:IEC 60664-1: 2020, IEC 61800-5-1: 2022, IEC 62109-1: 2010
- Hall effect current sensors are mainly used in industrial automation output 50mA power supply ±12V ±15V
more...
|
| CR1A 100 H01 |
100 |
±200 |
±12...15 |
±50...100mA |
±0.5 |
200 |
-40~85 |
Ø23 |
|
JK126-500-3P |
- Closed loop(compensated)current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion losses
- Standards:IEC 60664-1: 2020, IEC 61800-5-1: 2022, IEC 62109-1: 2010
- Supply voltage ±12V·±15V JK126-500-3P connection
- Low voltage hall effect based linear current sensor
more...
|
| CS3A 100 P00 |
100 |
±150 |
±12...15 |
±100...150mA |
±0.3 |
150 |
-40~85 |
13.5 x 10 mm |
+ |
|
- Closed loop (compensated) current sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion loss
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
- High accuracy hall effect current tranducer primary busbar 13.5x10.0mm based on PCB mount type
more...
|
| CS3A 125 P00 |
125 |
±200 |
±12...15 |
±125...200mA |
±0.3 |
150 |
-40~85 |
13.5 x 10 mm |
+ |
|
- Closed loop (compensated) current sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion loss
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
- High bandwidth current sensor and low offset drift over temperature PCB installation
more...
|
| CR1A 200 H00 |
200 |
±400 |
±12...15 |
±100...200mA |
±0.5 |
200 |
-40~85 |
Ø23 |
|
MOLEX 5045-04A |
- Closed loop (compensated) current sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion loss
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
- Magnetic current sensors suppliers supply voltage: 12 - 15V output100 mA
more...
|
| CR1A 200 H01 |
200 |
±400 |
±12...15 |
±100...200mA |
±0.5 |
200 |
-40~85 |
Ø23 |
|
JK126-500-3P |
- Closed loop (compensated) current sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- 200A hall effect analog current sensor very good linearity for measurements
- High accuracy
- Very low offset drift over temperature
- No insertion loss
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
- Hall effect analog current sensor very good linearity for measurements
-
more...
|
| CM1A 200 H00 |
200 |
±420 |
±12...15 |
±100...210mA |
±0.2 |
100 |
-40~85 |
Ø15.6 |
|
Molex 6410 |
- Closed loop (compensated) current sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion loss
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
- China professional high-frequency current transducers factory
more...
|
| CR1A 300 H00 |
300 |
±500 |
±12...15 |
±150...250mA |
±0.5 |
200 |
-40~85 |
Ø23 |
|
MOLEX 5045-04A |
- Closed loop (compensated) current sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion loss
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
- Low voltage high accuracy wide input range 100A-300A through hole type current transducer
more...
|
| CR1A 300 H01 |
300 |
±500 |
±12...15 |
±150...250mA |
±0.5 |
200 |
-40~85 |
Ø23 |
|
JK126-500-3P |
- Closed loop (compensated) current sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion loss
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
- High accurate hall effect AC/DC power supply ±12 V ~ ±15V through-hole type current sensor
more...
|
| CR1A 300 H02 |
300 |
±500 |
±12...15 |
±150...250mA |
±0.5 |
200 |
-40~85 |
Ø23 |
|
HX39600-3Y |
- Closed loop (compensated) current sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion loss
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
- Hall effect sensors analog circuit design measure Current Using Current Sensors
-
more...
|
| CM2A 300 H00 |
300 |
±500 |
±12...20 |
±150...250mA |
±0.3 |
100 |
-40~85 |
Ø20 |
|
Molex 6410 |
- Closed loop(compensated)current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion losses
- Standards:IEC 60664-1: 2020, IEC 61800-5-1: 2022, IEC 62109-1: 2010
- Hall effect current transducersupply voltage ±12 ±20V input 300A CT
more...
|
| CR2A 400 H00 |
400 |
±600 |
±15...24 |
±100...150mA |
±0.5 |
100 |
-40~85 |
Ø35.0 |
|
JK126-500-3P |
- Closed loop(compensated)current sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion loss
- Measuring range 300A-500A ±15V ±24Vcurrent transducer
more...
|
| CR2A 500 H00 |
500 |
±800 |
±15...24 |
±100...160mA |
±0.5 |
100 |
-40~85 |
Ø35.0 |
|
JK126-500-3P |
- Closed loop(compensated)current sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion loss
- Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
- Low voltage high accuracy current measurement device 500A closed-loop current sensors
more...
|
| CM3A 500 H00 |
500 |
±800 |
±15...24 |
±100...160mA |
±0.5 |
100 |
-40~85 |
Ø30 |
|
Molex 6410 |
- Closed loop (compensated) current sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion loss
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
- Current sensor CT measures direct current flow using the hall effect renewable energy, electric vehicles, and power monitoring
more...
|
| CM3A 500 H01 |
500 |
±800 |
±15...24 |
±100...160mA |
±0.5 |
100 |
-40~85 |
Ø30 |
|
JST B3P VH |
- Closed loop (compensated) current sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion loss
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
- Hall current measurement device 500A low current consumption
more...
|
| CM4A 1000 H00 |
1000 |
±2100 |
±15...24 |
±200...420mA |
±0.3 |
150 |
-40~85 |
Ø38 |
|
Molex 6410 |
- Closed loop(compensated)current sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion loss
- Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
- Closed-loop current transducers supplier low voltage measuring 1000A
more...
|
| CM4A 1000 H03 |
1200 |
±1800 |
±24 |
±300...450mA |
±0.4 |
150 |
-40~85 |
Ø38 |
|
JST B3P VH |
- Closed loop(compensated)current sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion loss
- Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
- High accuracy wide applications fileds closed-loop hall effect current sensor 1000A supply voltage ±24
more...
|
| CM4A 1000 H05 |
1000 |
±2100 |
±15...24 |
±200...420mA |
±0.3 |
150 |
-40~85 |
Ø38 |
|
JST B3P VH |
- Closed loop(compensated)current sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion loss
- Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
- Professional current transducer supplier for rail transit system
more...
|
| CM5A 2000 H20 |
2000 |
±4250 |
±15...24 |
±400...850mA |
±0.3 |
150 |
-40~85 |
Ø57.5 |
|
JST B3P VH |
- Closed loop (compensated) current sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion loss
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
- Hall effect DC current measurement device high accuracy reliable current transducer
more...
|
| HS1V 50 H00 |
50 |
±150 |
±12...15 |
±4V |
±1.0 |
50 |
-40~105 |
20x10 mm |
|
MOLEX 5045-04A |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
- Industrial current transducer products high accuracystability top performance and effective cost
more...
|
| HS1V 50 H05 |
50 |
±150 |
±12...15 |
±4V |
±1.0 |
50 |
-40~105 |
20x10 mm |
|
MOLEX 5045-04A |
- Open loop sensor using the Hall Effect
- Output voltage is proportional to supply voltage
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion loss
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
- Excellent accuracy easy use, high reliability output ±4V 50A, 100A, 200A, 300A, 400A, 500A, 600A current sensor
more...
|
| HS1V 100 H05 |
100 |
±300 |
±12...15 |
±4V |
±1.0 |
50 |
-40~105 |
20x10 mm |
|
MOLEX 5045-04A |
- Open loop sensor using the Hall Effect
- Output voltage is proportional to supply voltage
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion loss
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
- Current sensors measuring electric current for protection of electrical equipment
more...
|
| HR1V 100 H01 |
100 |
±200 |
±12...15 |
±5V |
±1.0 |
20 |
-40~85 |
Ø20 |
|
JK2EDG-5.08-4P |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion loss
- Small size
- Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
- Current sensors rely on open-loop hall effect technology
more...
|
| HS1V 200 H00 |
200 |
±600 |
±12...15 |
±4V |
±1.0 |
50 |
-40~105 |
20x10 mm |
|
MOLEX 5045-04A |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
- Factory sale open loop capacitive sensor for electronic measurement of current supply voltage ± 12V ± 15V
more...
|
| HS1V 200 H05 |
200 |
±600 |
±12...15 |
±4V |
±1.0 |
50 |
-40~105 |
20x10 mm |
|
MOLEX 5045-04A |
- Open loop sensor using the Hall Effect
- Output voltage is proportional to supply voltage
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion loss
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
- Open-loop easy mounting small size and saves space hall current sensor
more...
|
| HS1V 50 H04 |
50 |
±150 |
±12...15 |
±4V |
±1.0 |
50 |
-40~105 |
20.4x10.4 mm |
|
XH2.54-4P |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
- Low temperature drift closed loop current sensor
more...
|
| HS2V 200 H05 |
200 |
±600 |
±15 |
±4V |
±1.0 |
25 |
-40~105 |
40.5x32.5 mm |
|
MOLEX 5045-04A |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
- Easy mounting small size
- open-loop Hall effect technology for industrial scenarios
more...
|
| HR1V 200 H01 |
200 |
±400 |
±12...15 |
±5V |
±1.0 |
20 |
-40~85 |
Ø20 |
|
JK2EDG-5.08-4P |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion loss
- Small size
- Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
- Current transducers for monitoring and control.
more...
|
| HS1V 300 H00 |
300 |
±900 |
±12...15 |
±4V |
±1.0 |
50 |
-40~105 |
20x10 mm |
|
MOLEX 5045-04A |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
- Hall effect principle supply voltage ±12V ±15V measures electrical currentfor battery management
more...
|
| HS1V 300 H05 |
300 |
±900 |
±12...15 |
±4V |
±1.0 |
50 |
-40~105 |
20x10 mm |
|
MOLEX 5045-04A |
- Open loop sensor using the Hall Effect
- Output voltage is proportional to supply voltage
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion loss
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
- Hall effect current sensor in EVs, inverters, and industrial controls for safety and accuracy
more...
|
| HR1V 300 H01 |
300 |
±600 |
±12...15 |
±5V |
±1.0 |
20 |
-40~85 |
Ø20 |
|
JK2EDG-5.08-4P |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion loss
- Small size
- Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
- Hall sensor offering higher accuracy and dynamic range
more...
|
| HS1V 400 H00 |
400 |
±900 |
±12...15 |
±4V |
+1.0 |
50 |
-40~105 |
20x10 mm |
|
MOLEX 5045-04A |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
- Direct factory Hall effect current sensor open loop series for welding applications
more...
|
| HR1V 400 H01 |
400 |
±800 |
±12...15 |
±5V |
±1.0 |
20 |
-40~85 |
Ø20 |
|
JK2EDG-5.08-4P |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion loss
- Small size
- Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
- New and original customizable 50A 100A 200A 300A 400A 500A Hall open loop current sensor
more...
|
| HS2V 500 H05 |
500 |
±1500A |
±15 |
±4V |
+1.0 |
25 |
-40~105 |
40.5x32.5 mm |
|
MOLEX 5045-04A |
- Open loop sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL94-V0
- No insertion loss
- Small size
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
- Different types current sensors
Detection range 200A-1500A, working voltage ±15V
more...
|
| HR1V 500 H01 |
500 |
±900 |
±12...15 |
±5V |
+1.0 |
20 |
-40~85 |
Ø20 |
|
JK2EDG-5.08-4P |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion loss
- Small size
- Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
- High precision and low drift hall current sensor
more...
|
| HS1V 600 H00 |
600 |
±900 |
±12...15 |
±4V |
+1.0 |
50 |
-40~105 |
20x10 mm |
|
MOLEX 5045-04A |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
- Current sensor used detects and measuresensure safety, efficiency, and proper operation of electrical systems
more...
|
| HS2V 600 H05 |
600 |
±1800 |
±15 |
±4V |
+1.0 |
25 |
-40~105 |
40.5x32.5 mm |
|
MOLEX 5045-04A |
- Open loop sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL94-V0
- No insertion loss
- Small size
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
- Wide frequency cost-effective open-loop high accuracy current sensor
more...
|
| HS3V 800 H00 |
800 |
+2400 |
±15 |
±4V |
+1.0 |
25 |
-40~85 |
64 x 21 mm |
|
MOLEX 5045-04A |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
- Current sensor detects electric current enabling monitoring and control
more...
|
| HS1V 50 H03 |
50 |
±150 |
±12...15 |
±4V |
±1.0 |
50 |
-40~105 |
20.4x10.4 mm |
|
RVV4*0.2mm*0.2mm - 500mm |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
- Low temperature drift closed loop current sensor
more...
|
| HS2V 1000 H05 |
1000 |
±2500 |
±15 |
±4V |
+1.0 |
25 |
-40~105 |
40.5x32.5 mm |
|
MOLEX 5045-04A |
- Open loop sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL94-V0
- No insertion loss
- Small size
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
- Analog output voltage current sensor for New market HVDC
more...
|
| HS2V 1500 H05 |
1500 |
±2500 |
±15 |
±4V |
±1.0 |
25 |
-40~105 |
40.5x32.5 mm |
|
MOLEX 5045-04A |
- Open loop sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL94-V0
- No insertion loss
- Small size
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
- Hall current sensor for motor control and telecommunication rectifiers
more...
|
| HS3V 1500 H00 |
1500 |
±4500 |
±15 |
±4V |
±1.0 |
25 |
-40~85 |
64 x 21 mm |
|
MOLEX 5045-04A |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
- High voltage 500-3000A current measurement sensor
more...
|
| HS3V 2000 H00 |
2000 |
±5500 |
±15 |
±4V |
±1 |
25 |
-40~85 |
64 x 21 mm |
|
MOLEX 5045-04A |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
- Hall effect open-loop technology current sensor for industrial applications
more...
|
| HS3V 3000 H00 |
3000 |
±5500 |
±15 |
±4V |
±1.0 |
25 |
-40~85 |
64 x 21 mm |
|
MOLEX 5045-04A |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
- Current sensor Measurement of 500A 600A 800A 1000A 1500A 2000A 2500A 3000A 15V power supply 4V
more...
|
| AS1V 30 H05 |
30 |
±30 |
5 |
2.5±0.625V |
+1 |
50 |
-40~105 |
20.5x10.5 mm |
|
RVVP 3×0.3mm×0.3mm-1000 |
- Open loop current sensor using the Hall Effect.
- Output voltage is proportional to the supply voltage
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- Supply voltage: +5V
- No insertion loss.
- Small size
- Standards: EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
- Current sensor with primary nominal rms current ±30A,Supply voltage 5V
more...
|
| AS1V 50 H00 |
50 |
±50 |
5 |
2.5±2V |
±1.0 |
50 |
-40~105 |
20.5x10.5 mm |
MOLEX 5045-04A |
|
- Open loop current sensor using the Hall Effect.
- Output voltage is proportional to the supply voltage
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- Supply voltage: +5V
- No insertion loss.
- Small size
- Standards: EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
- High performance current sensor for EV HEV BMS
more...
|
| AS1V 50 H01 |
50 |
±150 |
5 |
2.5±0.625V |
±1.0 |
50 |
-40~105 |
20.5x10.5 mm |
MOLEX 5045-04A |
|
- Open loop current sensor using the Hall Effect.
- Output voltage is proportional to the supply voltage
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- Supply voltage: +5V
- No insertion loss.
- Small size
- Standards: EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
- Industrial grade bidirectional current sensor for AI data center industrial internet
more...
|
| AS1V 100 H00 |
100 |
±100A |
5 |
2.5±2 |
±1.0 |
50 |
-40~105 |
20.5 x 10.5 mm |
|
MOLEX 5045-04A |
- Open loop current sensor using the Hall Effect.
- Output voltage is proportional to the supply voltage
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- Supply voltage: +5V
- No insertion loss.
- Small size
- Standards: EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
- Battery powered 5V portable industrial grade current sensor wide measurement range for Industrial application fields
more...
|
| AS1V 100 H01 |
100 |
±300 |
5 |
2.5±0.625V |
±1.0 |
50 |
-40~105 |
20.5 x 10.5 mm |
|
MOLEX 5045-04A |
- Open loop current sensor using the Hall Effect.
- Output voltage is proportional to the supply voltage
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- Supply voltage: +5V
- No insertion loss.
- Small size
- Standards: EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
- Current sensor for industrial environment
more...
|
| AS1V 100 H07 |
100 |
±100 |
5 |
2.5±0.625V |
±1.0 |
50 |
-40~105 |
20.5 x 10.5 mm |
|
RVVP 3 x 0.3mmx 0.3mm -600 |
- Open loop current sensor using the Hall Effect
Galvanic separation between primary and secondary Insulating plastic case recognized according to UL 94-V0 Supply voltage:+5V No insertion loss Small size Standards: IEC 60664-1:2020 IEC 61800-5-1:2022 IEC 62109-1:2010 - Current sensors for various applications
more...
|
| AN1V 150 PB501 |
150 |
150 |
5 |
0.55...4.55V |
±1.0 |
250 |
-40~125 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- ASIC Technology.
- Maintain output proportional to changes in the power supply(include offset and sensitivity).
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Small size.
- Standards: IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
- Hall effect current transducer
more...
|
| AS1V 200 H00 |
200 |
±200 |
5 |
2.5±2V |
±1.0 |
50 |
-40~105 |
20.5x10.5 mm |
|
Molex 5045-04A |
- Open loop current sensor using the Hall Effect.
- Output voltage is proportional to the supply voltage
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- Supply voltage: +5V
- No insertion loss.
- Small size
- Standards: EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
- How the current sensor works in robotics
more...
|
| AS1V 200 H01 |
200 |
±600 |
5 |
2.5±0.625V |
±1.0 |
50 |
-40~105 |
20.5x10.5 mm |
|
Molex 5045-04A |
- Open loop current sensor using the Hall Effect.
- Output voltage is proportional to the supply voltage
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- Supply voltage: +5V
- No insertion loss.
- Small size
- Standards: EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
- Electric current sneosr current sensing circuit diagram
more...
|
| AS1V 200 H07 |
200 |
±200 |
5 |
2.5±0.625V |
±1.0 |
50 |
-40~105 |
20.5x10.5 mm |
|
RVVP 3 x 0.3mm x 0.3mm -600 |
- Open loop current sensor using the Hall Effect
Galvanic separation between primary and secondary Insulating plastic case recognized according to UL 94-V0 Supply voltage:+5V No insertion loss Small size Standards: IEC 60664-1:2020 IEC 61800-5-1:2022 IEC 62109-1:2010 - High accuracy current sensor core electronic component for Battery Management System
more...
|
| AS1V 300 H00 |
300 |
±300 |
5 |
2.5±2V |
±1.0 |
50 |
-40~105 |
20.5 x 10.5 mm |
|
MOLEX 5045-04A |
- Open loop current sensor using the Hall Effect.
- Output voltage is proportional to the supply voltage
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- Supply voltage: +5V
- No insertion loss.
- Small size
- Standards: EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
- Welding power supply current sampling hall sensor
more...
|
| AS1V 300 H01 |
300 |
±900 |
5 |
2.5±0.625V |
±1.0 |
50 |
-40~105 |
20.5 x 10.5 mm |
|
MOLEX 5045-04A |
- Open loop current sensor using the Hall Effect.
- Output voltage is proportional to the supply voltage
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- Supply voltage: +5V
- No insertion loss.
- Small size
- Standards: EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
- Open-loop current sensor for electric vehicle charging station
more...
|
| AS1V 400 H00 |
400 |
±400 |
5 |
2.5±2V |
±1.0 |
50 |
-40~105 |
20.5 x 10.5 mm |
|
MOLEX 5045-04A |
- Open loop current sensor using the Hall Effect.
- Output voltage is proportional to the supply voltage
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- Supply voltage: +5V
- No insertion loss.
- Small size
- Standards: EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
- Hall effect DC and AC current transducer for overcurrent protection circuit
more...
|
| AS1V 400 H01 |
400 |
±900 |
5 |
2.5±0.625V |
±1.0 |
50 |
-40~105 |
20.5 x 10.5 mm |
|
MOLEX 5045-04A |
- Open loop current sensor using the Hall Effect.
- Output voltage is proportional to the supply voltage
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- Supply voltage: +5V
- No insertion loss.
- Small size
- Standards: EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
- Current sensor component for industrial control
more...
|
| AS1V 500 H00 |
500 |
±500 |
5 |
2.5±2V |
±1.0 |
50 |
-40~105 |
20.5 x 10.5 mm |
|
MOLEX 5045-04A |
- Open loop current sensor using the Hall Effect.
- Output voltage is proportional to the supply voltage
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- Supply voltage: +5V
- No insertion loss.
- Small size
- Standards: EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
- Current sensor for monitor the operating conditions of the motors
more...
|
| AS1V 500 H01 |
500 |
±900 |
5 |
2.5±0.625V |
±1.0 |
50 |
-40~105 |
20.5 x 10.5 mm |
|
MOLEX 5045-04A |
- Open loop current sensor using the Hall Effect.
- Output voltage is proportional to the supply voltage
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- Supply voltage: +5V
- No insertion loss.
- Small size
- Standards: EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
- Primary hole type currrent sensor with fast response, supply voltage+5V, real-time monitoring
more...
|
| AS1V 600 H00 |
600 |
±600 |
5 |
2.5±2V |
±1.0 |
50 |
-40~105 |
20.5 x 10.5 mm |
|
MOLEX 5045-04A |
- Open loop current sensor using the Hall Effect.
- Output voltage is proportional to the supply voltage
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- Supply voltage: +5V
- No insertion loss.
- Small size
- Standards: EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
- Lightweight low loss motor control open loop high precision current sensor for AC variable speed
more...
|
| AS1V 600 H01 |
600 |
±900 |
5 |
2.5±0.625V |
±1.0 |
50 |
-40~105 |
20.5 x 10.5 mm |
|
MOLEX 5045-04A |
- Open loop current sensor using the Hall Effect.
- Output voltage is proportional to the supply voltage
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- Supply voltage: +5V
- No insertion loss.
- Small size
- Standards: EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
- Panel mounted current sensors
more...
|
| AS1V 700 H00 |
700 |
±700 |
5 |
2.5±2V |
±1.0 |
50 |
-40~105 |
20.5 x 10.5 mm |
|
MOLEX 5045-04A |
- Open loop current sensor using the Hall Effect.
- Output voltage is proportional to the supply voltage
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- Supply voltage: +5V
- No insertion loss.
- Small size
- Standards: EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
- Current sensor HASS 700-S +5V
more...
|
| AS1V 800 H00 |
800 |
±800 |
5 |
2.5±2V |
±1.0 |
50 |
-40~105 |
20.5 x 10.5 mm |
|
MOLEX 5045-04A |
- Open loop current sensor using the Hall Effect.
- Output voltage is proportional to the supply voltage
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- Supply voltage: +5V
- No insertion loss.
- Small size
- Standards: EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
- Hall effect sensor for electric scooter motor uninterruptible power supplies
more...
|
| VN2A 25 P01 |
5mA |
7mA |
24 |
±25mA |
±0.8 |
|
-40~85 |
NA |
+ |
|
- Closed loop (compensated) voltage sensor using the Hall Effect
- Insulating plastic case recognized according to UL94-V0
- Single power supply:+24V
- No insertion loss
- Small size
- High accuracy
- Very good linearity
- Very low offset drift over temperature
- High output frequency bandwidth
- Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
- Voltage sensor with good temperature stability
more...
|
| VN2A 25 P00 |
10mA |
±14mA |
±15 |
±25mA |
±0.6 |
|
-40~85 |
NA |
+ |
|
- Closed loop (compensated) voltage sensor using the Hall Effect.
- Insulating plastic case recognized according to UL94-V0.
- No insertion loss.
- Small size.
- High accuracy.
- Very good linearity.
- Very low offset drift over temperature.
- High output frequency bandwidth.
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
- Isolated voltage sensor for welding machine power control
more...
|
| VN2A 25 P02 |
10mA |
±14mA |
24 |
±25mA |
±0.8 |
|
-40~85 |
NA |
+ |
|
- Closed loop (compensated) voltage sensor using the Hall Effect
- Insulating plastic case recognized according to UL94-V0
- No insertion loss
- Small size
- High accuracy
- Very good linearity
- Very low offset drift over temperature
- High output frequency bandwidth
- Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
- Compact small size closed loop voltage sensor for PCB mount
more...
|
| VN2A 400 PB02 |
400V |
±400V |
±12 |
±5V |
±0.6 |
|
-40~85 |
NA |
|
3 Faston 6.3 x 0.8mm |
- Closed loop (compensated) voltage sensor using the Hall Effect
- Insulating plastic case recognized according to UL94-V0
- Small size
- High accuracy
- Supply voltage +12V
- Very good linearity
- Very low offset drift over temperature.
- Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
- Voltage sensor factory wholesale for power electronics
more...
|
| VN2A 800 PB00 |
800V |
±1400V |
±12...15 |
±25mA |
±0.6 |
|
-40~85 |
NA |
|
3 Faston 6.3 x 0.8mm |
- Closed loop (compensated) voltage sensor using the Hall Effect
- Insulating plastic case recognized according to UL94-V0
- Small size
- High accuracy
- Very good linearity
- Very low offset drift over temperature
- Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
- Voltage sensor ±12V ±15V ±0.6% accuracy closed loop hall effect for Industrial drives
more...
|
| VN2A 800 PB01 |
800V |
±1400V |
24 |
4V |
±0.6 |
|
-40~85 |
NA |
|
3 Faston 6.3 x 0.8mm |
- Closed loop (compensated) voltage sensor using the Hall Effect
- Insulating plastic case recognized according to UL94-V0
- Small size
- High accuracy
- Supply voltage +24V
- Very good linearity
- Very low offset drift over temperature.
- Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
- Wide range voltage sensor for power monitoring
more...
|
| VN2A 1100 PB00 |
1100V |
±1500V |
±12...15 |
±25mA |
±0.6 |
|
-40~85 |
NA |
|
3 Faston 6.3 x 0.8mm |
- Closed loop (compensated) voltage sensor using the Hall Effect
- Insulating plastic case recognized according to UL94-V0
- Small size
- High accuracy
- Very good linearity
- Very low offset drift over temperature
- Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
- Replacement voltage sensor same pin to pin for energy storage PCS
more...
|
| VN2A 1100 PB03 |
1100V |
±1500V |
±15 |
±4V |
±0.6 |
|
-40~85 |
NA |
|
3 Faston 6.3 x 0.8mm |
- Closed loop (compensated) voltage sensor using the Hall Effect
- Insulating plastic case recognized according to UL 94-V0
- Small size
- High accuracy
- Supply voltage:±15V
- Very good linearity
- Very low offset drift over temperature
- Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
- Voltage sensor circuit diagram
more...
|
| VN2A 1100 PB20 |
1100V |
±1100V |
±12 |
±4V |
±0.6 |
|
-40~85 |
NA |
|
XH-3A |
- Closed loop (compensated) voltage sensor using the Hall Effect
- Insulating plastic case recognized according to UL94-V0
- Small size
- High accuracy
- Very good linearity
- Very low offset drift over temperature
- Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
- Industrial voltage sensor for power supply monitoring system
more...
|
| HK1V 200 H00 |
200 |
±400 |
±12...15 |
±4V |
±1.0 |
10 |
-40~85 |
Ø40.5 |
|
15EDGVC-3.5-04P |
- Open loop sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion loss
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
- High voltage power distribution 200A current transducer
more...
|
| HK1V 400 H00 |
400 |
±800 |
±12...15 |
±4V |
±1.0 |
10 |
-40~85 |
Ø40.5 |
|
15EDGVC-3.5-04P |
- Open loop sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion loss
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
- Industrial current sensor for power supply monitoring system
more...
|
| HK1V 600 H00 |
600 |
±1200 |
±12...15 |
±4V |
±1.0 |
10 |
-40~85 |
Ø40.5 |
|
15EDGVC-3.5-04P |
- Open loop sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion loss
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
- Wide range open loop split core current sensor suitable for energy storage
more...
|
| HK1V 800 H00 |
800 |
±1600 |
±12...15 |
±4V |
±1.0 |
10 |
-40~85 |
Ø40.5 |
|
15EDGVC-3.5-04P |
- Open loop sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion loss
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
- No power-off installation split core current sensor
more...
|
| HK1V 1000 H00 |
1000 |
±2000 |
±12...15 |
±4V |
±1.0 |
10 |
-40~85 |
Ø40.5 |
|
15EDGVC-3.5-04P |
- Open loop sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion loss
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
- Factory price open loop hall effect current sensor for distribution cabinet
more...
|
| HK1V 2000 H00 |
2000 |
±4000 |
±12...15 |
±4V |
±1.0 |
10 |
-40~85 |
Ø40.5 |
|
15EDGVC-3.5-04P |
- Open loop sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion loss
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
- AC current measurement, 0-5V / 4-20mA output available split core current sensor
more...
|
| HK1V 200 H01 |
200 |
±400 |
±12...15 |
±5V |
±1.0 |
10 |
-40~85 |
Ø40.5 |
|
15EDGVC-3.5-04P |
- Open loop sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion loss
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
- China open loop current sensor manufacturer
more...
|
| HK1V 400 H01 |
400 |
±800 |
±12...15 |
±5V |
±1.0 |
10 |
-40~85 |
Ø40.5 |
|
15EDGVC-3.5-04P |
- Open loop sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion loss
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
- Compact small size current sensor
more...
|
| HK1V 600 H01 |
600 |
±1200 |
±12...15 |
±5V |
±1.0 |
10 |
-40~85 |
Ø40.5 |
|
15EDGVC-3.5-04P |
- Open loop sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion loss
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
- Split structure current sensor for energy storage PCS
more...
|
| HK1V 800 H01 |
800 |
±1600 |
±12...15 |
±5V |
±1.0 |
10 |
-40~85 |
Ø40.5 |
|
15EDGVC-3.5-04P |
- Open loop sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion loss
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
- Low drift voltage transducer IEC61010 CE RoHS
more...
|
| HK1V 1000 H01 |
1000 |
±2000 |
±12...15 |
±5V |
±1.0 |
10 |
-40~85 |
Ø40.5 |
|
15EDGVC-3.5-04P |
- Open loop sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion loss
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
- Measure AC/DC split core Hall current sensor 200A 400A 500A 600A 800A 1000A 2000A linearity and accuracy ±1 %
more...
|
| HK1V 2000 H01 |
2000 |
±4000 |
±12...15 |
±5V |
±1.0 |
10 |
-40~85 |
Ø40.5 |
|
15EDGVC-3.5-04P |
- Open loop sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion loss
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
- Hot selling open type wide range current transducer supplier
more...
|
| HS1V 500 H05 |
500 |
±900 |
±12...15 |
±4V |
±1.0 |
50 |
-40~105 |
20.4x10.4 mm |
|
MOLEX 5045-04A |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Open loop hall effect current sensor 50A~600A with galvanic isolation for EV, BESS & solar inverterapplications
more...
|
| HS1V 500 H06 |
500 |
±900 |
±12...15 |
±4V |
±1.0 |
50 |
-40~105 |
20.4x10.4 mm |
|
XH-4A |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
High accuracy hall current sensor module 500A analog output ±4V for battery energy storage systems (BESS)
more...
|
| HS1V 500 H08 |
500 |
±900 |
±12...15 |
±4V |
±1.0 |
50 |
-40~105 |
20.4x10.4 mm |
|
RVV4*0.2mm*0.2mm + HC-VH-T |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
-
- Closed loop and open loop hall effect current sensor
more...
|
| HS1V 500 H09 |
500 |
±900 |
±12...15 |
±4V |
±1.0 |
50 |
-40~105 |
20.4x10.4 mm |
|
RVV4*0.2mm*0.2mm - 700mm |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
CHIPSENSE Open loop hall sensor factory AC/DC 500A current input 4V output for meters
more...
|
| HS2V 500 H01 |
500 |
±1500 |
±15 |
±4V |
±1.0 |
25 |
-40~105 |
40.5x32.5 mm |
|
RVVP 4*0.3mm*0.3mm- 1500mm |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
DC 4V hall current detection sensor 500A
more...
|
| HS2V 500 H02 |
500 |
±1500 |
±15 |
±4V |
±1.0 |
25 |
-40~105 |
40.5x32.5 mm |
|
XH-4A |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Solar panel battery charge controller using current sensor
more...
|
| HS3V 500 H00 |
500 |
±1500 |
±15 |
±4V |
±1.0 |
25 |
-40~85 |
64 x 21 mm |
|
MOLEX 5045-04A |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Hall effect open loop current sensor manufacturer for high efficiency power electronics
more...
|
| HS3V 500 H01 |
500 |
±1500 |
±15 |
±4V |
±1.0 |
25 |
-40~85 |
64 x 21 mm |
|
XH-4A |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Industrial current transducer supplier for energy storage PCS,BMS
more...
|
| HS1V 600 H02 |
600 |
±900 |
±12...15 |
±4V |
±1.0 |
50 |
-40~105 |
20.4x10.4 mm |
|
MOLEX 5045-04A |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Open loop current sensor 600a hall effect linear use case for multi-phase inverters
more...
|
| AN3V 10 PB30 |
10 |
±25 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
High permeability Hall effect transducer measure AC/DC current for EV charging pile
more...
|
| HS1V 600 H08 |
600 |
±900 |
±12...15 |
±4V |
±1.0 |
50 |
-40~105 |
20.4x10.4 mm |
|
RVV4*0.2mm*0.2mm + HC-VH-T |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
AC frequency transducer capacitive open loop hall busbar sensor
more...
|
| HS1V 600 H06 |
600 |
±900 |
±12...15 |
±4V |
±1.0 |
50 |
-40~105 |
20.4x10.4 mm |
|
XH-4A |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
High precision open loop linear variable differential transformer current sensor ±1%
more...
|
| HS1V 600 H05 |
600 |
±900 |
±12...15 |
±4V |
±1.0 |
50 |
-40~105 |
20.4x10.4 mm |
|
MOLEX 5045-04A |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
How to use a current sensor?
more...
|
| HS1V 600 H04 |
600 |
±900 |
±12...15 |
±4V |
±1.0 |
50 |
-40~105 |
20.4x10.4 mm |
|
XH2.54-4P |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
How electric current senso works?
more...
|
| HS1V 600 H03 |
600 |
±900 |
±12...15 |
±4V |
±1.0 |
50 |
-40~105 |
20.4x10.4 mm |
|
RVV4*0.2mm*0.2mm - 500mm |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Electronic components current sensor 600A 1 channel hall effect open loop bidirectional For AC/DC through hole 20.4mm×10.4mm
more...
|
| HS1V 50 H02 |
50 |
±150 |
±12...15 |
±4V |
±1.0 |
50 |
-40~105 |
20.4x10.4 mm |
|
MOLEX 5045-04A |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
- Electronically measuring DC, AC, various industrial applications current transducer
more...
|
| HS1V 50 H06 |
50 |
±150 |
±12...15 |
±4V |
±1.0 |
50 |
-40~105 |
20.4x10.4 mm |
|
XH-4A |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
- Open-loop vs Closed-loop current sensor comparison
more...
|
| HS1V 50 H08 |
50 |
±150 |
±12...15 |
±4V |
±1.0 |
50 |
-40~105 |
20.4x10.4 mm |
|
RVV4*0.2mm*0.2mm + HC-VH-T |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
- Low zero drift, customized service current sensor for PCS
more...
|
| HS1V 50 H09 |
50 |
±150 |
±12...15 |
±4V |
±1.0 |
50 |
-40~105 |
20.4x10.4 mm |
|
RVV4*0.2mm*0.2mm - 700mm |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
- High accuracy current sensors stable performance over full temperature range
more...
|
| HS1V 100 H00 |
100 |
±300 |
±12...15 |
±4V |
±1.0 |
50 |
-40~105 |
20.4x10.4 mm |
|
MOLEX 5045-04A |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
- China's open-loop current sensor for welding machine
more...
|
| HS1V 100 H02 |
100 |
±300 |
±12...15 |
±4V |
±1.0 |
50 |
-40~105 |
20.4x10.4 mm |
|
MOLEX 5045-04A |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
- Wide range AC DC measurement
more...
|
| HS1V 100 H03 |
100 |
±300 |
±12...15 |
±4V |
±1.0 |
50 |
-40~105 |
20.4x10.4 mm |
|
RVV4*0.2mm*0.2mm - 500mm |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
- Current sensor used in HVDC application
more...
|
| HS1V 100 H04 |
100 |
±300 |
±12...15 |
±4V |
±1.0 |
50 |
-40~105 |
20.4x10.4 mm |
|
XH2.54-4P |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Hall-effect sensors (isolated, non-contact) and resistive shunt sensors (direct measurement)
more...
|
| HS1V 100 H06 |
100 |
±300 |
±12...15 |
±4V |
±1.0 |
50 |
-40~105 |
20.4x10.4 mm |
|
XH-4A |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
DC current measuring device
more...
|
| HS1V 100 H08 |
100 |
±300 |
±12...15 |
±4V |
±1.0 |
50 |
-40~105 |
20.4x10.4 mm |
|
RVV4*0.2mm*0.2mm + HC-VH-T |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Types of Hall Effect DC Current Sensors in automotive, industrial, and power systems
more...
|
| HS1V 100 H09 |
100 |
±300 |
±12...15 |
±4V |
±1.0 |
50 |
-40~105 |
20.4x10.4 mm |
|
RVV4*0.2mm*0.2mm - 700mm |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
High accuracy current sensors used for measuring current with cable 700mm primary hole 20.4mm×10.4mm
more...
|
| HS1V 200 H02 |
200 |
±600 |
±12...15 |
±4V |
±1.0 |
50 |
-40~105 |
20.4x10.4 mm |
|
MOLEX 5045-04A |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
What are the main types of current sensors?
more...
|
| HS1V 200 H03 |
200 |
±600 |
±12...15 |
±4V |
±1.0 |
50 |
-40~105 |
20.4x10.4 mm |
|
RVV4*0.2mm*0.2mm - 500mm |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
How electric current sensor technology works?
more...
|
| HS1V 200 H04 |
200 |
±600 |
±12...15 |
±4V |
±1.0 |
50 |
-40~105 |
20.4x10.4 mm |
|
XH2.54-4P |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
3μs Fast response ±12V ±15V hall current sensor 50kHz bandwidth low drift hall current sensor for industrial application
more...
|
| HS1V 200 H06 |
200 |
±600 |
±12...15 |
±4V |
±1.0 |
50 |
-40~105 |
20.4x10.4 mm |
|
XH-4A |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
±1% Accuracy supply voltage ±12V ±15V current sensor -40℃ to 105℃ , 6.6kV impulse withstand current sensor
more...
|
| HS1V 200 H08 |
200 |
±600 |
±12...15 |
±4V |
±1.0 |
50 |
-40~105 |
20.4x10.4 mm |
|
RVV4*0.2mm*0.2mm + HC-VH-T |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Easy install compact current sensor output wire length 700±20mm for energy storage system
more...
|
| HS1V 200 H09 |
200 |
±600 |
±12...15 |
±4V |
±1.0 |
50 |
-40~105 |
20.4x10.4 mm |
|
RVV4*0.2mm*0.2mm - 700mm |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
OEM current sensor with wire from professional hall current sensor supplier
more...
|
| HS2V 200 H01 |
200 |
±600 |
±15 |
±4V |
±1.0 |
25 |
-40~105 |
40.5x32.5 mm |
|
RVVP 4*0.3mm*0.3mm- 1500mm |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Open loop current sensor supply voltage+4V,output line length 150m for Static converters for DC motor drives
more...
|
| HS2V 200 H02 |
200 |
±600 |
±15 |
±4V |
±1.0 |
25 |
-40~105 |
40.5x32.5 mm |
|
XH-4A |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Primary hole 40.5mm×32.5mm current transformer used for charge integration and condition monitoring of rechargeable batteries
more...
|
| HS1V 300 H02 |
300 |
±900 |
±12...15 |
±4V |
±1.0 |
50 |
-40~105 |
20.4x10.4 mm |
|
MOLEX 5045-04A |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
The type of output used by a current sensor depends on the desired application and operating environment
more...
|
| HS1V 300 H03 |
300 |
±900 |
±12...15 |
±4V |
±1.0 |
50 |
-40~105 |
20.4x10.4 mm |
|
RVV4*0.2mm*0.2mm - 500mm |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Types of Current Sensors and Their Advantages and Disadvantages
more...
|
| HS1V 300 H04 |
300 |
±900 |
±12...15 |
±4V |
±1.0 |
50 |
-40~105 |
20.4x10.4 mm |
|
XH2.54-4P |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Measurement Range 50A to 600A compact design for panel mounting and integration into existing systems.
more...
|
| HS1V 300 H06 |
300 |
±900 |
±12...15 |
±4V |
±1.0 |
50 |
-40~105 |
20.4x10.4 mm |
|
XH-4A |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
±150A to ±900A primary current measuring range12V 15V supply voltage (±5%) ±4V analog output voltage current transformer
more...
|
| HS1V 300 H08 |
300 |
±900 |
±12...15 |
±4V |
±1.0 |
50 |
-40~105 |
20.4x10.4 mm |
|
RVV4*0.2mm*0.2mm + HC-VH-T |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
±4V output open loop Hall effect current sensor 50A to 600A bidirectional measurement
more...
|
| HS1V 300 H09 |
300 |
±900 |
±12...15 |
±4V |
±1.0 |
50 |
-40~105 |
20.4x10.4 mm |
|
RVV4*0.2mm*0.2mm - 700mm |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Fast response RoHS CE compliant current sensor for welding power supply and SMPS,output voltage is proportional to the supply voltage
more...
|
| HS1V 400 H02 |
400 |
±900 |
±12...15 |
±4V |
±1.0 |
50 |
-40~105 |
20.4x10.4 mm |
|
MOLEX 5045-04A |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Types and Characteristics of Current Sensors
more...
|
| HS1V 400 H03 |
400 |
±900 |
±12...15 |
±4V |
±1.0 |
50 |
-40~105 |
20.4x10.4 mm |
|
RVV4*0.2mm*0.2mm - 500mm |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Current measurement methods
more...
|
| HS1V 400 H04 |
400 |
±900 |
±12...15 |
±4V |
±1.0 |
50 |
-40~105 |
20.4x10.4 mm |
|
XH2.54-4P |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
High precision current transducer high reliability current sensor Φ4.5 mm through hole for harsh environment -40℃ to 105℃
more...
|
| HS1V 400 H05 |
400 |
±900 |
±12...15 |
±4V |
±1.0 |
50 |
-40~105 |
20.4x10.4 mm |
|
MOLEX 5045-04A |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Reinforced insulation current sensor miniature current sensor Φ4.5 mm through-hole for space‑constrained power module
more...
|
| HS1V 400 H06 |
400 |
±900 |
±12...15 |
±4V |
±1.0 |
50 |
-40~105 |
20.4x10.4 mm |
|
XH-4A |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Power Supply current sensor ±12V ±15V supply reliable and precise solution for industrial current measurement
more...
|
| HS1V 400 H08 |
400 |
±900 |
±12...15 |
±4V |
±1.0 |
50 |
-40~105 |
20.4x10.4 mm |
|
RVV4*0.2mm*0.2mm + HC-VH-T |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Wholesale open loop current sensor China manufacturers, suppliers, factory
more...
|
| HS1V 400 H09 |
400 |
±900 |
±12...15 |
±4V |
±1.0 |
50 |
-40~105 |
20.4x10.4 mm |
|
RVV4*0.2mm*0.2mm - 700mm |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Power Supply current sensor ±12V ±15V supply reliable and precise solution for industrial current measurement
more...
|
| HS2V 400 H00 |
400 |
±1200 |
±15 |
±4V |
±1.0 |
25 |
-40~105 |
40.5x32.5 mm |
|
MOLEX 5045-04A |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Wholesale open loop current sensor China manufacturers, suppliers, factory
more...
|
| HS2V 400 H01 |
400 |
±1200 |
±15 |
±4V |
±1.0 |
25 |
-40~105 |
40.5x32.5 mm |
|
RVVP 4*0.3mm*0.3mm- 1500mm |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Compact current transducers AC and DC currents ranging from 200 A to 1500 A
more...
|
| HS2V 400 H02 |
400 |
±1200 |
±15 |
±4V |
±1.0 |
25 |
-40~105 |
40.5x32.5 mm |
|
XH-4A |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Current transducer measurement range 200A to 1500A Easy installation bipolar power supply ±15V for Power supplies for welding applications
more...
|
| HS1V 500 H00 |
500 |
±900 |
±12...15 |
±4V |
±1.0 |
50 |
-40~105 |
20.4x10.4 mm |
|
MOLEX 5045-04A |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Low temperature drift ±4V output analog current sensor for BMS UPS SMPS
more...
|
| HS1V 500 H02 |
500 |
±900 |
±12...15 |
±4V |
±1.0 |
50 |
-40~105 |
20.4x10.4 mm |
|
MOLEX 5045-04A |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Molex connector 50kHz bandwidth current sensor for AC DC pulsed current for easy PCB installation
more...
|
| HS1V 500 H03 |
500 |
±900 |
±12...15 |
±4V |
±1.0 |
50 |
-40~105 |
20.4x10.4 mm |
|
RVV4*0.2mm*0.2mm - 500mm |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
How to choose a current sensor for EV inverter and custom current sensor solution
more...
|
| HS1V 500 H04 |
500 |
±900 |
±12...15 |
±4V |
±1.0 |
50 |
-40~105 |
20.4x10.4 mm |
|
XH2.54-4P |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Compatible alternative open cloop 500A current sensor isolated for EV, solar inverter and industrial automation
more...
|
| HS1V 600 H09 |
600 |
±900 |
±12...15 |
±4V |
±1.0 |
50 |
-40~105 |
20.4x10.4 mm |
|
RVV4*0.2mm*0.2mm - 700mm |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
High efficiency 600A current sensor for solar wind hybrid inverter
more...
|
| HS2V 600 H01 |
600 |
±1800 |
±15 |
±4V |
±1.0 |
25 |
-40~105 |
40.5x32.5 mm |
|
RVVP 4*0.3mm*0.3mm- 1500mm |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Smart grid 600A hall effect current transducer for renewable energy
more...
|
| HS2V 600 H02 |
600 |
±1800 |
±15 |
±4V |
±1.0 |
25 |
-40~105 |
40.5x32.5 mm |
|
XH-4A |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Automation and controls sensors and switches for automation current sensors
more...
|
| HS3V 600 H00 |
600 |
±1800 |
±15 |
±4V |
±1.0 |
25 |
-40~85 |
64 x 21 mm |
|
MOLEX 5045-04A |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Hybrid Battery Pack Current Sensing DC4V Hall Effect Current Sensor
more...
|
| HS3V 600 H01 |
600 |
±1800 |
±15 |
±4V |
±1.0 |
25 |
-40~85 |
64 x 21 mm |
|
XH-4A |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
AC current sensor factory price 600A output current sensor from China current sensor supplier
more...
|
| HS2V 800 H00 |
800 |
±2400 |
±15 |
±4V |
±1.0 |
25 |
-40~105 |
40.5x32.5 mm |
|
MOLEX 5045-04A |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Customizable high reliability compliant industrial output analog 800A current sensor for industrial applications
more...
|
| HS2V 800 H01 |
800 |
±2400 |
±15 |
±4V |
±1.0 |
25 |
-40~105 |
40.5x32.5 mm |
|
RVVP 4*0.3mm*0.3mm- 1500mm |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
800-S Hall effect open loop current sensor ±15V 20mA Bidirectional chassis mount
more...
|
| HS2V 800 H02 |
800 |
±2400 |
±15 |
±4V |
±1.0 |
25 |
-40~105 |
40.5x32.5 mm |
|
XH-4A |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Replacement HAT 800-S HAT series current transformer, 800A input, 40.5mm×32.5mm, 15 V for wind energy inverter
more...
|
| HS3V 800 H01 |
800 |
±2400 |
±15 |
±4V |
±1.0 |
25 |
-40~85 |
64 x 21 mm |
|
XH-4A |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
High-performance open loop Hall effect current sensors designed for industrial power electronics and renewable energy systems
more...
|
| HS2V 1000 H01 |
1000 |
±3000 |
±15 |
±4V |
±1.0 |
25 |
-40~105 |
40.5x32.5 mm |
|
RVVP 4*0.3mm*0.3mm- 1500mm |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Wide current range 200-1500A core components of power conversion equipment
more...
|
| HS2V 1000 H02 |
1000 |
±3000 |
±15 |
±4V |
±1.0 |
25 |
-40~105 |
40.5x32.5 mm |
|
XH-4A |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Primary nominal rms current 1000 A ±15 V supply ±4 V output −40 °C to +105 °C CT current transformer
more...
|
| HS3V 1000 H00 |
1000 |
±3000 |
±15 |
±4V |
±1.0 |
25 |
-40~85 |
64 x 21 mm |
|
MOLEX 5045-04A |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
High resistance 500 A to 3000 A primary hole 64mm×21mm ±4 V output 1000A current sensor
more...
|
| HS3V 1000 H01 |
1000 |
±3000 |
±15 |
±4V |
±1.0 |
25 |
-40~85 |
64 x 21 mm |
|
XH-4A |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Professional current sensors supplier
more...
|
| HS2V 1200 H00 |
1200 |
±2500 |
±15 |
±4V |
±1.0 |
25 |
-40~105 |
40.5x32.5 mm |
|
MOLEX 5045-04A |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Buy reliable current sensors. compact design, high accuracy, wide application in power supply, inverter and industrial fields. factory direct wholesale.
more...
|
| HS2V 1200 H01 |
1200 |
±3000 |
±15 |
±4V |
±1.0 |
25 |
-40~105 |
40.5x32.5 mm |
|
RVVP 4*0.3mm*0.3mm- 1500mm |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Industrial AC DC pulse current sensor 200A to 1500A IEC standard current transducer RVVP 4×0.3mm² shielded wire
more...
|
| HS2V 1200 H02 |
1200 |
±3000 |
±15 |
±4V |
±1.0 |
25 |
-40~105 |
40.5x32.5 mm |
|
XH-4A |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Open loop 200A-1500A current sensor secondary connection XH-4A cost-effective alternative to HAT-S series
more...
|
| HS2V 1500 H01 |
1500 |
±3000 |
±15 |
±4V |
±1.0 |
25 |
-40~105 |
40.5x32.5 mm |
|
RVVP 4*0.3mm*0.3mm- 1500mm |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Industrial grade easy installation current sensor AC DC current transducer output line length 1500 ±20mm
more...
|
| HS2V 1500 H02 |
1500 |
±3000 |
±15 |
±4V |
±1.0 |
25 |
-40~105 |
40.5x32.5 mm |
|
XH-4A |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Compact current sensor module precise current transducer 200A -1500A for renewable energy systems
more...
|
| HS3V 1500 H01 |
1500 |
±4500 |
±15 |
±4V |
±1.0 |
25 |
-40~85 |
64 x 21 mm |
|
XH-4A |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
In solar and wind power generation systems, current sensors are used to optimize energy conversion and ensure system safety.
more...
|
| HS3V 2000 H01 |
2000 |
±5500 |
±15 |
±4V |
±1.0 |
25 |
-40~85 |
64 x 21 mm |
|
XH-4A |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Original factory agent of current sensor offers domestic alternative design solution services.
more...
|
| HS3V 2500 H00 |
2500 |
±5500 |
±15 |
±4V |
±1.0 |
25 |
-40~85 |
64 x 21 mm |
|
MOLEX 5045-04A |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
What are major types of current sensors
more...
|
| HS3V 2500 H01 |
2500 |
±5500 |
±15 |
±4V |
±1.0 |
25 |
-40~85 |
64 x 21 mm |
|
XH-4A |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
AC/DC current transducer
more...
|
| HS3V 3000 H01 |
3000 |
±5500 |
±15 |
±4V |
±1.0 |
25 |
-40~85 |
64 x 21 mm |
|
XH-4A |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
3000A current sensor for large-scale energy storage projects and industrial power systems
more...
|
| CR1V 75 PB05 |
75 |
±180 |
5 |
2.5V |
±1.0 |
200 |
-40~105 |
NA |
+ |
|
- Closed loop(compensated)current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion losses
- Standards:IEC 60664-1: 2020, IEC 61800-5-1: 2022, IEC 62109-1: 2010
Current sensor circuit diagram
more...
|
| CR1V 6 PB02 |
6 |
±12 |
5 |
1.65±1.25V |
±0.4 |
200 |
-40~85 |
NA |
+ |
|
- Closed loop(compensated)current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion losses
- Standards:IEC 60664-1: 2020, IEC 61800-5-1: 2022, IEC 62109-1: 2010
Reliable data output voltage current sensor to ensure accurate system status monitoring and stable operation
more...
|
| CR1V 6 PB03 |
6 |
±12 |
5 |
1.62±1.25V |
±0.7 |
200 |
-40~85 |
NA |
+ |
|
- Closed loop(compensated)current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion losses
- Standards:IEC 60664-1: 2020, IEC 61800-5-1: 2022, IEC 62109-1: 2010
IEC 60664-1 certified current transducer PCB mount current sensor for industrial test equipment
more...
|
| CR1V 6 PB04 |
6 |
±20 |
5 |
2.5±1.875V |
±0.8 |
200 |
-40~105 |
NA |
+ |
|
- Closed loop(compensated)current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion losses
- Standards:IEC 60664-1: 2020, IEC 61800-5-1: 2022, IEC 62109-1: 2010
CAT III reinforced insulation current transducer compact PCB mount isolated current sensor for BMS manufacturer
more...
|
| CR1V 15 PB02 |
15 |
±30 |
5 |
1.65±1.25V |
±0.4 |
200 |
-40~85 |
NA |
+ |
|
- Closed loop(compensated)current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion losses
- Standards:IEC 60664-1: 2020, IEC 61800-5-1: 2022, IEC 62109-1: 2010
Factory direct high precision measurement CTs
more...
|
| CR1V 15 PB03 |
15 |
±30 |
5 |
1.62±1.25V |
±0.7 |
200 |
-40~85 |
NA |
+ |
|
- Closed loop(compensated)current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion losses
- Standards:IEC 60664-1: 2020, IEC 61800-5-1: 2022, IEC 62109-1: 2010
Current sensor CL 15A AC/DC compact design, easy to install PCB for servo motor drives
more...
|
| CR1V 15 PB04 |
15 |
±51 |
5 |
2.5±1.875V |
±0.8 |
200 |
-40~105 |
NA |
+ |
|
- Closed loop(compensated)current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion losses
- Standards:IEC 60664-1: 2020, IEC 61800-5-1: 2022, IEC 62109-1: 2010
China supplier single power supply 5V hall effect DC/AC 6-50A current sensor for welding machine power supply
more...
|
| CR1V 25 PB02 |
25 |
±50 |
5 |
1.65±1.25V |
±0.4 |
200 |
-40~85 |
NA |
+ |
|
- Closed loop(compensated)current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion losses
- Standards:IEC 60664-1: 2020, IEC 61800-5-1: 2022, IEC 62109-1: 2010
China factory price hall effect current measurement 500A closed loop DC AC hallcurrent sensor manufacturer
more...
|
| AT4V 150 H00 |
150 |
±450 |
±12...15 |
±4V |
±1.0 |
50 |
-40~105 |
10 x 12mm(Three holes) |
|
HX PZ2.54-1X6P WZ |
- Three-phase open loop current sensor using the Hall effect
- Operating temperature range:-40℃~ 105℃
- Insulating plastic case recognized according to UL 94-V0
- Voltage ratio output
- Very good linearity
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
more...
|
| HK1A 400 H00 |
400 |
±480 |
12 |
4...20mA |
±1.0 |
DC |
-25~85 |
Ø41.3 |
|
2EDGV-3.81-4P |
- Open loop sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion loss
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Clamp-on current transformer
more...
|
| CR1V 25 PB04 |
25 |
±85 |
5 |
2.5±1.875V |
±0.8 |
200 |
-40~105 |
NA |
+ |
|
- Closed loop(compensated)current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion losses
- Standards:IEC 60664-1: 2020, IEC 61800-5-1: 2022, IEC 62109-1: 2010
High precision hall effect current sensor for new energy combiner box measurement
more...
|
| CR1V 50 PB03 |
50 |
±100 |
5 |
1.62±1.25V |
±0.7 |
200 |
-40~85 |
NA |
+ |
|
- Closed loop(compensated)current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion losses
- Standards:IEC 60664-1: 2020, IEC 61800-5-1: 2022, IEC 62109-1: 2010
Hall effect current transducer PCB type for EV Charger PV Solar Motor UPS PLC DSP
more...
|
| CR1V 50 PB04 |
50 |
±150 |
5 |
2.5±1.875V |
±0.8 |
200 |
-40~105 |
NA |
+ |
|
- Closed loop(compensated)current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion losses
- Standards:IEC 60664-1: 2020, IEC 61800-5-1: 2022, IEC 62109-1: 2010
Understanding basics current sensing circuits
more...
|
| CS3A 50 P00 |
50 |
±90 |
±12...15 |
±50...90mA |
±0.3 |
150 |
-40~85 |
13.5 x 10 mm |
+ |
|
- Closed loop (compensated) current sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion loss
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Electrical parameter table accuracy ±0.3% 150kHz bandwidth response time 0.5μs mechanical dimension drawing primary busbar 13.5x10mm outline size
more...
|
| CS3A 50 P21 |
50 |
±100 |
±12...15 |
±25...37.5mA |
±0.3 |
150 |
-40~85 |
13.5 x 10 mm |
+ |
|
- Closed loop (compensated) current sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion loss
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Current sensor dimension diagram secondary pin layout recommended PCB hole Φ1.0mm mounted on energy storage PCS DC busbar current detection
more...
|
| CS3A 100 P21 |
100 |
±150 |
±12...15 |
±50...75mA |
±0.3 |
150 |
-40~85 |
13.5 x 10 mm |
+ |
|
- Closed loop (compensated) current sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion loss
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Recommended PCB hole high accuracy primary nominal rms current ±100A for battery management frequency bandwidth 150 kHz for power supplies for welding applications
more...
|
| CS3A 100 P51 |
100 |
±150 |
±12...15 |
±100...150mA |
±0.3 |
150 |
-40~85 |
13.5 x 10 mm |
+ |
|
- Closed loop (compensated) current sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion loss
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Current transducer components in stock
more...
|
| CN1A 25 PB01 |
25 |
±36 |
±12 |
±25mA |
±0.5 |
150 |
-40~85 |
NA |
+ |
|
- Closed loop (compensated) current sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion loss
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Alternative supplier for current transducers LA 25-np series
more...
|
| CN2A 25 PB02 |
25 |
±55 |
±12...15 |
±25mA |
±0.5 |
200 |
-40~85 |
NA |
+ |
|
- Closed loop (compensated) current sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion loss
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Main application fields of closed loop current snesor for UPS, BMS, servo, wind inverter
more...
|
| CN2A 40 PB02 |
40 |
±90 |
±12...15 |
±40mA |
±0.5 |
200 |
-40~85 |
NA |
+ |
|
- Closed loop (compensated) current sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion loss
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
PCB mount hall sensor equivalent to LAH-P high linearity hall transducer for battery management system BMS fast response 0.5μs
more...
|
| CN2A 50 PB02 |
50 |
±90 |
±12...15 |
±50mA |
±0.5 |
200 |
-40~85 |
NA |
+ |
|
- Closed loop (compensated) current sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion loss
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Panel mounted EV battery BMS tester current sensor
more...
|
| CR1A 50 H00 |
50 |
±70 |
±12...15 |
±50...100mA |
±0.5 |
200 |
-40~85 |
Ø23 |
|
MOLEX 5045-04A |
- Closed loop (compensated) current sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion loss
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
AC DC current transducer for inverter
more...
|
| CR1A 100 H02 |
100 |
±200 |
±12...15 |
±50...100mA |
±0.5 |
200 |
-40~85 |
Ø23 |
|
HX39600-3Y |
- Closed loop (compensated) current sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion loss
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Isolated hall effect current sensor primary current 100A for new energy vehicle
more...
|
| CR1A 100 H04 |
100 |
±200 |
±12...15 |
±50...100mA |
±0.5 |
200 |
-40~85 |
Ø23 |
|
Molex9652048 3.96-A4A |
- Closed loop (compensated) current sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion loss
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Special through-core current transformer for frequency converter
more...
|
| CR1A 200 H02 |
200 |
±400 |
±12...15 |
±100...200mA |
±0.5 |
200 |
-40~85 |
Ø23 |
|
HX39600-3Y |
- Closed loop (compensated) current sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion loss
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Domestic high precision current transducer 300±20mm RVV cable current transducer alternative to LT x08-S7 series
more...
|
| CR1A 200 H04 |
200 |
±400 |
±12...15 |
±100...200mA |
±0.5 |
200 |
-40~85 |
Ø23 |
|
Molex9652048 3.96-A4A |
- Closed loop (compensated) current sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion loss
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Molex connector closed loop hall current sensor ±200A fast response 0.5μs for industrial converter
more...
|
| CR1A 300 H04 |
300 |
±500 |
±12...15 |
±150...250mA |
±0.5 |
200 |
-40~85 |
Ø23 |
|
Molex9652048 3.96-A4A |
- Closed loop (compensated) current sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion loss
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Compact mountable 300A hall current sensor with molex connector swapable LT x08-S7 series
more...
|
| CM1A 100 H01 |
100 |
±200 |
±12...15 |
±100...200mA |
±0.2 |
100 |
-40~85 |
Ø15.6 |
|
Molex 6410 |
- Closed loop (compensated) current sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion loss
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Primary busbar through hole alternative LF 205/210-Series 100A current sensor easy installation
more...
|
| CM1A 200 H02 |
200 |
±420 |
±12...15 |
±100...200mA |
±0.2 |
100 |
-40~85 |
Ø15.6 |
|
Molex Minifit 5566 |
- Closed loop (compensated) current sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion loss
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Primary hole Φ15.6 mm global leader in current measurement solutions
more...
|
| CM4A 1000 H06 |
1000 |
±2700 |
±15...24 |
±200...540mA |
±0.3 |
150 |
-40~85 |
Ø38 |
|
Molex 6410 |
- Closed loop(compensated)current sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion loss
- Standards:EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
Choosing the right current sensor type depends on the application’s requirements for accuracy, range, installation method, and integration needs
more...
|
| CM5A 2000 H01 |
2000 |
±3850 |
±15...24 |
±400...770mA |
±0.3 |
150 |
-40~85 |
Ø57.5 |
|
5566-4A |
- Closed loop (compensated) current sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion loss
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Low thermal drift compatible LF 2005/2010-series hall effect current sensor 100kHz bandwidth SMPS application ±2000A 6kV isolation 150kHz bandwidth
more...
|
| CM5A 2000 H21 |
2000 |
±4250 |
±15...24 |
±400...850mA |
±0.3 |
150 |
-40~85 |
Ø57.5 |
|
2EDGV-5.08-3P |
- Closed loop (compensated) current sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion loss
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Drop-in replacement LF 2005/2010-series hall effect transducers for MW UPS & large scale energy storage
more...
|
| CS3A 200 P21 |
200 |
±300 |
±12...15 |
±100...150mA |
±0.3 |
150 |
-40~85 |
13.5 x 10 mm |
+ |
|
- Closed loop (compensated) current sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion loss
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Professional manufacturer equivalent to S25P150D15Y board mount closed-loop hall effectcurrent sensor for AI data center and power electronics
more...
|
| CS1V 80 P00 |
80 |
±270 |
5 |
0.25...4.75V |
<1 |
>200 |
-40~85 |
NA |
+ |
|
- Closed loop (compensated) multi-range current sensor using the Hall Effect
- Voltage output
- Unipolar supply voltage 5V
- PCB-mount isolated current transducer for ac and dc up to 300A
- Aperture for primary conductor
- Galvanic insulation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion loss
- Standards:
- IEC 60664-1: 2020
- IEC 61800-5-1: 2022
- IEC 62109-1: 2010
- UL listed
more...
|
| CS1V 100 P00 |
100 |
±270 |
5 |
2.5±0.625V |
<1 |
>200 |
-40~85 |
NA |
+ |
|
- Closed loop (compensated) multi-range current sensor using the Hall Effect
- Voltage output
- Unipolar supply voltage 5V
- PCB-mount isolated current transducer for ac and dc up to 300A
- Aperture for primary conductor
- Galvanic insulation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion loss
- Standards:
- IEC 60664-1: 2020
- IEC 61800-5-1: 2022
- IEC 62109-1: 2010
- UL listed
more...
|
| CS1V 150 P00 |
150 |
±270 |
5 |
2.5±0.625V |
<1 |
>200 |
-40~85 |
NA |
+ |
|
- Closed loop (compensated) multi-range current sensor using the Hall Effect
- Voltage output
- Unipolar supply voltage 5V
- PCB-mount isolated current transducer for ac and dc up to 300A
- Aperture for primary conductor
- Galvanic insulation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion loss
- Standards:
- IEC 60664-1: 2020
- IEC 61800-5-1: 2022
- IEC 62109-1: 2010
- UL listed
more...
|
| CS1V 200 P00 |
200 |
±450 |
5 |
2.5±0.625V |
<1.1 |
>200 |
-40~85 |
NA |
+ |
|
- Closed loop (compensated) multi-range current sensor using the Hall Effect
- Voltage output
- Unipolar supply voltage 5V
- PCB-mount isolated current transducer for ac and dc up to 300A
- Aperture for primary conductor
- Galvanic insulation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion loss
- Standards:
- IEC 60664-1: 2020
- IEC 61800-5-1: 2022
- IEC 62109-1: 2010
- UL listed
more...
|
| CS1V 100 PB00 |
100 |
±270 |
5 |
2.5±0.625 |
<0.95 |
>200 |
-40~85 |
4 x φ5.2 mm |
+ |
|
- Closed loop (compensated) multi-range current sensor using the Hall Effect
- Voltage output
- Unipolar supply voltage 5V
- Integrated primary conductor for PCB soldering
- Galvanic insulation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion loss
- Standards:
- IEC 60664-1: 2020
- IEC 61800-5-1: 2022
- IEC 62109-1: 2010
- UL listed
more...
|
| CS1V 150 PB00 |
150 |
±270 |
5 |
2.5±0.625 |
<0.95 |
>200 |
-40~85 |
4 x φ5.2 mm |
+ |
|
- Closed loop (compensated) multi-range current sensor using the Hall Effect
- Voltage output
- Unipolar supply voltage 5V
- Integrated primary conductor for PCB soldering
- Galvanic insulation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion loss
- Standards:
- IEC 60664-1: 2020
- IEC 61800-5-1: 2022
- IEC 62109-1: 2010
- UL listed
more...
|
| CS1V 200 PB00 |
200 |
±450 |
5 |
2.5±0.625V |
<1.1 |
>200 |
-40~85 |
4 x φ5.2 mm |
+ |
|
- Closed loop (compensated) multi-range current sensor using the Hall Effect
- Voltage output
- Unipolar supply voltage 5V
- Integrated primary conductor for PCB soldering
- Galvanic insulation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion loss
- Standards:
- IEC 60664-1: 2020
- IEC 61800-5-1: 2022
- IEC 62109-1: 2010
- UL listed
more...
|
| CS1V 250 P00 |
250 |
±380 |
5 |
2.5±0.625V |
<1.1 |
>200 |
-40~85 |
21x11.5 mm |
+ |
|
- Closed loop (compensated) multi-range current sensor using the Hall Effect
- Voltage output
- Unipolar supply voltage 5V
- PCB-mount isolated current transducer for ac and dc up to 300A
- Aperture for primary conductor
- Galvanic insulation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion loss
- Standards:
- IEC 60664-1: 2020
- IEC 61800-5-1: 2022
- IEC 62109-1: 2010
- UL listed
more...
|
| AT4V 50 H00 |
50 |
±150 |
±12...15 |
±4V |
±1.0 |
50 |
-40~105 |
10 x 12mm(Three holes) |
|
HX PZ2.54-1X6P WZ |
- Three-phase open loop current sensor using the Hall effect
- Operating temperature range:-40℃~ 105℃
- Insulating plastic case recognized according to UL 94-V0
- Voltage ratio output
- Very good linearity
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
more...
|
| AT4V 75 H00 |
75 |
±225 |
±12...15 |
±4V |
±1.0 |
50 |
-40~105 |
10 x 12mm(Three holes) |
|
HX PZ2.54-1X6P WZ |
- Three-phase open loop current sensor using the Hall effect
- Operating temperature range:-40℃~ 105℃
- Insulating plastic case recognized according to UL 94-V0
- Voltage ratio output
- Very good linearity
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
more...
|
| AT4V 100 H00 |
100 |
±300 |
±12...15 |
±4V |
±1.0 |
50 |
-40~105 |
10 x 12mm(Three holes) |
|
HX PZ2.54-1X6P WZ |
- Three-phase open loop current sensor using the Hall effect
- Operating temperature range:-40℃~ 105℃
- Insulating plastic case recognized according to UL 94-V0
- Voltage ratio output
- Very good linearity
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
more...
|
| HK1A 200 H00 |
200 |
±240 |
12 |
4...20mA |
±1.0 |
DC |
-25~85 |
Ø41.3 |
|
2EDGV-3.81-4P |
- Open loop sensor using the Hall Effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion loss
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Bidirectional easy assembly split core AC DC pulse current measuring sensor CHCS-EKF 200A for battery management system BMS SMPS UPS
more...
|
| CS1V 300 P00 |
300 |
±600 |
5 |
2.5±0.9375V |
<0.8 |
>200 |
-40~85 |
21x11.5 mm |
+ |
|
- Closed loop (compensated) multi-range current sensor using the Hall Effect
- Voltage output
- Unipolar supply voltage 5V
- PCB-mount isolated current transducer for ac and dc up to 300A
- Aperture for primary conductor
- Galvanic insulation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion loss
- Standards:
- IEC 60664-1: 2020
- IEC 61800-5-1: 2022
- IEC 62109-1: 2010
- UL listed
more...
|
| CS1V 80 PB00 |
80 |
±270 |
5 |
2.5±0.625V |
<1 |
200 |
-40~85 |
NA |
+ |
|
- Closed loop (compensated) multi-range current sensor using the Hall Effect
- Voltage output
- Unipolar supply voltage 5V
- Integrated primary conductor for PCB soldering
- Galvanic insulation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- Very good linearity
- High accuracy
- Very low offset drift over temperature
- No insertion loss
- Standards:
- IEC 60664-1: 2020
- IEC 61800-5-1: 2022
- IEC 62109-1: 2010
- UL listed
more...
|
| AN5V 60 PB00 |
60 |
±180 |
±12...15 |
±4V |
±1 |
50 |
-40~85 |
NA |
+ |
|
- 60A open loop current sensor using the Hall Effect
- Supply voltage ±12...±15V
- Galvanic insulation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion loss
- Small size
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
more...
|
| AN5V 30 PB00 |
30 |
±90 |
±12...15 |
±4V |
±1.0 |
50 |
-40~85 |
NA |
+ |
|
- 30A open loop current sensor using the Hall Effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion loss.
- Small size.
- Standards:
- EN50178: 1997
- IEC 61010-1: 2000
- UL 508: 2010
- Small size current sensors employed in solar inverters and battery management systems
more...
|
| AN5V 10 PB00 |
10 |
±30 |
±12...15 |
±4V |
±1.0 |
50 |
-40~85 |
NA |
+ |
|
- 10A open loop current sensor using the Hall Effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion loss.
- Small size.
- Standards:
- EN50178: 1997
- IEC 61010-1: 2000
- UL 508: 2010
- AC and DC currents sensor in automotive and industrial applications
more...
|
| CM8A 1000 H01 |
1000 |
±2400 |
±15...24 |
±200mA |
±0.4 |
DC...100 |
-40~85 |
Φ42mm |
|
M6 |
- Closed loop(compensated)current sensor using theHall effect
- Galvanic insulation between primary and secondary
- Insulating plastic case recognized according to UL94-V0
- Very good linearity
- Very low offset drift over temperature
- No insertion loss
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
more...
|
| HS3V 1200 H01 |
1200 |
±3600 |
±15 |
±4V |
±1.0 |
25 |
-40~85 |
64 x 21 mm |
|
XH-4A |
- Open loop current sensor using the Hall effect
- Galvanic separation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion losses
- Small size
- Standards:IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
In solar and wind power generation systems, current sensors are used to optimize energy conversion and ensure system safety.
more...
|