I. This standard marks the first time new-energy locomotives are regulated at the "complete vehicle" level.
On September 24, 2026, the National Railway Administration issued a standard titled "New-Energy Rolling Stock – Locomotives" (designated TB/T 3629—2026). Following reports by official media outlets on November 12, the standard garnered significant attention across the industry. It represents the first technical standard in my country’s railway sector to address new-energy locomotives at the complete-vehicle level. According to official statements, this standard fills a gap in the existing industry-standard framework for this field.

The scope of this standard is broader than that of typical product standards, it encompasses the entire life-cycle—from design, development, and testing/validation to manufacturing, operation, and maintenance. It covers operational conditions, classification and nomenclature, the overall locomotive structure, critical systems, and inspection and testing protocols. Its applicability has also been explicitly expanded to include railway transport across diverse industrial settings—such as steel, metallurgy, mining, power generation, coal, and port operations—moving beyond a narrow focus on mainline railways.
During the drafting process, three specific thematic areas were established: technical requirements for new-energy propulsion systems, energy-efficiency evaluation, and the assessment of energy consumption and operational range. Taken together, these themes point to a clear, central issue for new-energy locomotives: the question is not merely whether they can "run," but rather how to rigorously evaluate the performance and economics of the propulsion system as a whole.
And the starting point for that evaluation lies in the voltage and current present on the DC bus.
II. No Standardized Bus Voltage for Such Locomotives
Urban rail transit is highly standardized, DC traction networks operate at nominal voltage levels of 750V or 1500V, with power supply equipment, rolling stock, and protection settings all designed around these specific figures. Mainline electrified railways, meanwhile, utilize a standardized 25kV AC system.
Industrial and mining environments, however, are a different matter. Internal railways at steel mills, narrow-gauge transport systems at mines, and freight-handling lines at ports each rely on diverse, pre-existing power supply configurations—some use overhead catenary systems, others employ third rails, and some lack electrification entirely, depending instead on self-contained power sources. When transitioning to new-energy locomotives, the configuration of the traction battery string—determined by range requirements and available space—varies in terms of the number of series-connected cells, which in turn results in different bus voltages.
Consequently, the bus voltage for these locomotives can range from several hundred volts to over a thousand volts, with no consistency across different projects. For the design of measurement points, this means there are no pre-existing, standardized voltage ranges to choose from, instead, the measurement range must be determined based on the specific voltage of each individual project.
Because a single standard must encompass such a wide variety of scenarios, it can only establish general principles rather than prescribing a specific bus voltage value for every possible application. In practical terms, this means that the specifications for measurement points must be recalculated for each individual project. This is not a matter of design redundancy, but rather a necessity dictated by the nature of the operating environments themselves.

III. Hall-effect voltage sensors measure current, not voltage
The datasheet for the CHIIPSENSE VN2A 25 P06 voltage sensor clarifies its operating principle right on the first page: when measuring voltage, the sensor actually measures a current that is proportional to the target voltage. In practice, an appropriately sized measurement resistor (R1) must be connected in series with the primary circuit.

The datasheet confirms this. Its rated primary current is ±5mA, with a maximum measurable current of ±7mA, the rated secondary output is ±25mA, and the turns ratio is 2500:500. Nowhere in the entire table is there a primary-side parameter expressed in "volts."
The operating principle is as follows: the voltage to be measured is applied across resistor R1, generating a current IP. This current flows through the sensor’s primary coil, establishing magnetic flux within the core. A closed-loop compensation mechanism on the secondary side then drives this magnetic flux back to zero, the compensation current required to achieve this serves as the output. Therefore, what the sensor actually measures is the current flowing through its primary side.
This leads to a direct conclusion: the measurement range is not determined by the product itself, but by R1. Specifically, R1 is calculated by dividing the full-scale voltage you wish to measure by 5mA. To measure 500 V, you would select an R1 of 10 kΩ, to measure 1500 V, you would choose 300kΩ.
There is another constraint hidden in the datasheet: the primary coil resistance, RP, is 300 Ω (at 85°C). This resistance is in series with R1, meaning the measured voltage is distributed between the two based on their resistance values. Only the portion of the voltage that drops across R1 corresponds to the calibrated ratio. The larger R1 is relative to RP, the smaller the share of voltage dropped across RP. When R1 is 25kΩ, RP accounts for approximately 1.2% of the total circuit resistance, when R1 is 3kΩ, this proportion rises to 9%. Furthermore, because RP consists of a copper coil, its resistance varies with temperature—increasing from approximately 243Ω at 25°C to 300Ω at 85°C, a change of over 20%. When R1 is small, this variation is amplified, resulting in significant gain drift.
The closed-loop compensation mechanism, however, effectively resolves the issues associated with the magnetic core. The compensation current generated on the secondary side establishes an opposing magnetic flux within the core, which cancels out the flux produced by the primary side, consequently, the core consistently operates in a state of near-zero magnetic flux. In this operating mode, the effects of non-linearity, hysteresis, and temperature drift inherent to the core material are significantly suppressed, enabling the closed-loop linearity error to be kept within the range of ±0.1% of IPN. The trade-off is that the secondary side must possess sufficient drive capability: the maximum allowable resistance on the secondary side is 320ohms at ±5mA, decreasing to 190 ohms at ±7mA—meaning that as the secondary current increases, the maximum load that can be driven decreases.
IV. Changing R1 Affects Three Parameters Simultaneously
First, the measurement range: this is the most intuitive effect—a larger R1 allows for the measurement of higher voltages.
Second, the utilization of the primary current IP: a larger R1 results in a lower IP for a given measured voltage. Meanwhile, the offset current—which has a fixed maximum value of ±0.2mA—represents an increasingly larger proportion of the primary current as R1 increases. For instance, if IP is 5mA, the 0.2mA offset accounts for 4%, if IP drops to 2.5mA, that same 0.2mA offset now accounts for 8%.
Third, the power dissipation of R1 itself: the power dissipated by R1 is equal to the measured voltage multiplied by the primary current, or alternatively, the square of the voltage divided by R1. For a 1500V full-scale range with an IP of 5mA, R1 would be 300kΩ, resulting in a power dissipation of 7.5W. This is not a negligible amount, a resistor continuously dissipating 7.5 W will reach a temperature significantly higher than the ambient environment.
The datasheet provides a comparison that clearly illustrates this: when measuring 250V, using an R1 of 25kΩ yields a measurement accuracy of 0.8% at 25°C, whereas using an R1 of 50kΩ results in an accuracy of 1.6%. Doubling the measurement range leads to a twofold decrease in accuracy.
A note of caution: the operating points used in the datasheet examples do not necessarily align with the rated values found in the parameter tables. When performing an actual design, you must verify the measurement range and primary current against the IPN (nominal primary current) and IPM (maximum primary current) values specified in the parameter tables, do not simply copy the figures from the examples.

V. The accuracy specification excludes offset and the error contributed by R1.
It is important to distinguish between three specific values in the parameter table: a gain error of ±0.4%, a non-linearity error of ±0.1% of IPN (excluding offset), and an accuracy figure of ±1% of IPN (also excluding offset). Offset current is listed separately at ±0.2mA. The temperature drift is ±0.15mA for the range of -25°C to 85°C, but this increases to ±0.30mA when the range is extended to -40°C to 85°C—meaning the specification doubles when the lower temperature limit is reduced by just 15 degrees. In industrial or outdoor settings—such as during winter or in unheated garages—the latter, broader-range figure is the one that should be used.
The phrase "excluding offset" is critical. It implies that the ±1% accuracy figure accounts only for the combined effects of gain and linearity, the absolute value of the zero-point offset must be added separately. At low primary current levels, the zero-point offset becomes the dominant factor rather than a negligible one.
Furthermore, all these specifications rely on an implicit assumption: that R1 is both accurate and stable.
However, R1 is neither part of the sensor nor included in the specification sheet. Any errors in its resistance value, temperature coefficient, or voltage coefficient will propagate directly through the entire measurement chain. In high-voltage applications, resistors are often constructed using thick-film or high-voltage thin-film technologies to withstand the required voltage and power, these typically have a poorer temperature coefficient than precision metal-film resistors. As R1 dissipates several watts of power, its temperature can rise by tens of degrees, causing its resistance value to drift accordingly.
Therefore, when performing an actual error budget analysis, the gain-related component should be calculated as follows: the sensor’s gain error, plus the initial resistance tolerance of R1, plus the product of R1’s temperature coefficient and its self-heating-induced temperature rise. All three factors must be accounted for, simply taking the ±0.4% figure from the specification sheet is insufficient.
VI. The insulation for the section involving R1 is the responsibility of the PCB designer.
The isolation specifications for CHIPSENSE VN2A 25 P06 voltage sensor are quite robust: an AC isolation withstand voltage of 4.2kVrms (for 1 minute), a transient withstand voltage of 16kV, a clearance of 19.5 mm, a creepage distance of 19.5 mm, and a Comparative Tracking Index (CTI) rating of IIIa. Application examples indicate suitability for 800V reinforced insulation or 1600 V basic insulation, under CAT III PD2 conditions.
However, these are device-level specifications, applying specifically to the isolation barrier between the primary and secondary sides.
R1 is an external component, the voltage being measured is applied directly across it. Whether the component’s package is adequate, whether the pad spacing is sufficient, whether the creepage distance to adjacent nets is enough, and—if a conformal coating is applied—what the voltage rating of that coating is—none of these details are covered in the sensor’s datasheet. It is up to the PCB designer to calculate and verify these parameters.
There is a subtle, easily overlooked implication here: to reduce self-heating, R1 is often implemented as a series string of multiple resistors. While this achieves the correct total resistance, the potential at the intermediate nodes becomes floating. Each resistor sits at a different potential relative to ground, with the resistor at the top of the string experiencing the highest voltage relative to ground. If one simply stops after confirming that the "total resistance" and "power rating" are sufficient, it is very easy to overlook the necessary creepage and clearance requirements.
VII. Key Parameters to Verify for This Type of Measurement Point
First, determine the actual range of the bus voltage, including the maximum operating voltage and any potential over-voltage conditions, do not calculate the value of R1 based solely on nominal voltage. If R1 is incorrectly specified, none of the subsequent performance metrics can be accurately assessed.
Second, calculate the power dissipation in R1. Power dissipation leads to a temperature rise due to self-heating, multiplying this temperature rise by the temperature coefficient reveals its specific contribution to the gain error. In applications with high power dissipation, both the configuration (series/parallel arrangements) and the component package must be considered.
Third, distinguish between parameters in the datasheet that include offset and those that do not. The zero-point error is amplified when operating at low current levels, note that the denominator used in calculations should be the rated value, not the instantaneous reading.
Fourth, explicitly include the resistance tolerance and temperature coefficient of R1 in your error budget—do not assume ideal characteristics. For high-voltage resistors, these two parameters are typically inferior to those of precision resistors.
Fifth, verify the insulation-to-ground, creepage distance, and potential distribution (in series configurations) for the R1 section, based on the actual maximum voltage. The isolation rating of a component applies only to the component itself, not to the entire circuit board.
References:
National Railway Administration, Announcement on the Issuance of "New Energy Rolling Stock Locomotives"(TB/T 3629—2026), November 12, 2026:
https://www.nra.gov.cn/xwzx/xwxx/xwlb/202611/t20261112_352351.shtml
CHIPSENSE VN2A 25 P06 Voltage Sensor Datasheet (Document No. 2801 000 00811, February 27, 2026)
National Railway Administration–Standards, Regulations, and Announcements Section:
https://www.nra.gov.cn/jglz/gcjg/fggz/index.shtml
IEC 61800-5-1:2022 Adjustable speed electrical power drive systems–Part 5-1:
Safety requirements – Electrical, thermal and energy
IEC 60664-1:2020 Insulation coordination for equipment within low-voltage supply systems – Part 1: Principles, requirements and tests
CHIPSENSEis a national high-tech enterprise that focuses on the research and development, production, and application of high-end current and voltage sensors, as well as forward research on sensor chips and cutting-edge sensor technologies. CHIPSENSEis committed to providing customers with independently developed sensors, as well as diversified customized products and solutions.