| AN5V 30 PB00 |
30 |
±90 |
±12...15 |
±4V |
±1.0 |
50 |
-40~85 |
NA |
+ |
|
- 30A open loop current sensor using the Hall Effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion loss.
- Small size.
- Standards:
- EN50178: 1997
- IEC 61010-1: 2000
- UL 508: 2010
Small size current sensors employed in solar inverters and battery management systems to manage power conversion and ensure efficient operation
more...
|
| AN5V 10 PB00 |
10 |
±30 |
±12...15 |
±4V |
±1.0 |
50 |
-40~85 |
NA |
+ |
|
- 10A open loop current sensor using the Hall Effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion loss.
- Small size.
- Standards:
- EN50178: 1997
- IEC 61010-1: 2000
- UL 508: 2010
These measure the strength of the magnetic field using a Hall element, producing a proportional voltage. They can measure both AC and DC currents and are common in automotive and industrial applications
more...
|
| AN3V 10 PB50 |
10 |
±25 |
5 |
2.5±2V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+5V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
Open loop current sensors use the simplest implementation of the Hall effect. They provide the smallest, lightest, and most cost effective current measurement solution while also having very low power consumption
more...
|
| AN5V 15 PB00 |
15 |
±45 |
±12...15 |
±4V |
±1.0 |
50 |
-40~85 |
NA |
+ |
|
- 15A open loop current sensor using the Hall Effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion loss.
- Small size.
- Standards:
- EN50178: 1997
- IEC 61010-1: 2000
- UL 508: 2010
ASIC current sensor is a current sensor based on the Hall effect, featuring high accuracy and stability. Its working principle is that current flows through a conductor and generates a magnetic field through the Hall effect. Then, the ASIC amplifies and corrects these signals to enhance the measurement accuracy. The advantages of ASIC current sensors include: Low heat generation: Due to the smaller resistance value, less heat is produced. Easy to use and simpler design. Compatibility
more...
|
| AN3V 16 PB50 |
16 |
±40 |
5 |
2.5±2V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+5V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
Supply voltage 5V Electrical Measuring Analog Module Current Voltage Small AC Current Transducer 10A 16A 20A 32A 40A 50A
more...
|
| AN5V 20 PB00 |
20 |
±60 |
±12...15 |
±4V |
±1.0 |
50 |
-40~85 |
NA |
+ |
|
- 20A open loop current sensor using the Hall Effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion loss.
- Small size.
- Standards:
- EN50178: 1997
- IEC 61010-1: 2000
- UL 508: 2010
High-performance transducers optimizing power extraction in MPPT and servo motor drives. Current transducers can provide numerous functions, so they are found in a wide variety of devices, systems, and industries. In addition to sensing, quantifying, and converting electrical current from one type to another, these devices can also help track motor control.
more...
|
| AN3V 20 PB50 |
20 |
±50 |
5 |
2.5±2V |
±1 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+5V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
ASIC current sensors are integrated circuits designed to measure current using Hall effect technology. They operate by passing a current through a conductor, generating a magnetic field that is detected by a sensor. The output signal is then amplified and corrected using an ASIC, which enhances accuracy and stability.
more...
|
| AN5V 25 PB00 |
25 |
±75 |
±12...15 |
±4V |
±1 |
50 |
-40~85 |
NA |
+ |
|
- 25A open loop current sensor using the Hall Effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion loss.
- Small size.
- Standards:
- EN50178: 1997
- IEC 61010-1: 2000
- UL 508: 2010
ASIC sensors are known for their low sensitivity error and offset, making them reliable for various applications. These sensors are advantageous due to their compact design and ability to provide precise current measurements without the need for additional insulation.
more...
|
| AS1V 30 H05 |
30 |
±30 |
5 |
2.5±0.625V |
+1 |
50 |
-40~105 |
20.5x10.5 mm |
|
RVVP 3×0.3mm×0.3mm-1000 |
- Open loop current sensor using the Hall Effect.
- Output voltage is proportional to the supply voltage
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- Supply voltage: +5V
- No insertion loss.
- Small size
- Standards: EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
Current sensor with primary nominal rms current ±30A,Supply voltage 5V, Connection of secondary RVVP 3×0.3mm² Shielded wire,Cable length 1000 ±10 mm.
more...
|
| AN3V 32 PB50 |
32 |
±80 |
5 |
2.5±2V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+5V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
Open loop current sensor small size wideMeasurement range 10A 16A 20A 32A 40A 50A low power consumption Frequency bandwidth 250kHz based on PCB mounting
more...
|
| AN3V 40 PB50 |
40 |
±100 |
5 |
2.5±2V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+5V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
A Hall effect current sensor is an electronic device used to measure electric current by detecting the magnetic field generated around a current-carrying conductor.
more...
|
| AN5V 50 PB00 |
50 |
±150 |
±12...15 |
±4V |
±1.0 |
50 |
-40~85 |
NA |
+ |
|
- Open loop current sensor using the Hall Effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion loss.
- Small size.
- Standards:
- EN50178: 1997
- IEC 61010-1: 2000
- UL 508: 2010
more...
|
| AN3V 50 PB30 |
50 |
±125 |
3.3 |
1.65±1.15V |
+1.0 |
250 |
-40~150 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
Hall Effect Current Sensor 3.3V Low Power 4.3kV Isolation current sensor module for power electronics for New Energy Industrial Automation
more...
|
| AN3V 50 PB50 |
50 |
±125 |
5 |
2.5±2V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+5V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
Supply voltage 5V current sensor for Servo Motor 4.3kV Isolation for Industrial Drive BMS and industrial control system
more...
|
| AS1V 50 H00 |
50 |
±50 |
5 |
2.5±2V |
±1.0 |
50 |
-40~105 |
20.5x10.5 mm |
MOLEX 5045-04A |
|
- Open loop current sensor using the Hall Effect.
- Output voltage is proportional to the supply voltage
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- Supply voltage: +5V
- No insertion loss.
- Small size
- Standards: EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
High performance primary hole 20.5mm×10.5mm current sensor for EV HEV BMS Current Sensor for industrial electronic devices 50A 100A 200A 300A 400A 500A 600A700A 800A
more...
|
| AS1V 50 H01 |
50 |
±150 |
5 |
2.5±0.625V |
±1.0 |
50 |
-40~105 |
20.5x10.5 mm |
MOLEX 5045-04A |
|
- Open loop current sensor using the Hall Effect.
- Output voltage is proportional to the supply voltage
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- Supply voltage: +5V
- No insertion loss.
- Small size
- Standards: EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
Industrial grade Bidirectional current 50A 100A 200A 300A 400A 500A 600Acurrent sensor electronic component Smart Current Sensor Real-time Monitoring Self-Calibration for AI Data Center IoT Industrial Internet
more...
|
| AN3V 80 PB55 |
80 |
±200 |
5 |
2.5±2V |
+1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- ASIC Technology.
- Maintain output proportional to changes in the power supply(include offset and sensitivity).
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Small size.
- Standards: IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Current sensor is an electronic device that measures the flow of electric current in a conductor and converts this measurement into a usable output signal, such as voltage or digital data. This output can be used for monitoring, control, or protection in various applications, including industrial automation, electric vehicles, and renewable energy systems.
more...
|
| AN3V 100 PB55 |
100 |
±250 |
5 |
2.5±2V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+5V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
more...
|
| AS1V 100 H00 |
100 |
±100A |
5 |
2.5±2 |
±1.0 |
50 |
-40~105 |
20.5 x 10.5 mm |
|
MOLEX 5045-04A |
- Open loop current sensor using the Hall Effect.
- Output voltage is proportional to the supply voltage
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- Supply voltage: +5V
- No insertion loss.
- Small size
- Standards: EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
more...
|
| AS1V 100 H01 |
100 |
±300 |
5 |
2.5±0.625V |
±1.0 |
50 |
-40~105 |
20.5 x 10.5 mm |
|
MOLEX 5045-04A |
- Open loop current sensor using the Hall Effect.
- Output voltage is proportional to the supply voltage
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- Supply voltage: +5V
- No insertion loss.
- Small size
- Standards: EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
more...
|
| AS1V 100 H07 |
100 |
±100 |
5 |
2.5±0.625V |
±1.0 |
50 |
-40~105 |
20.5 x 10.5 mm |
|
RVVP 3 x 0.3mmx 0.3mm -600 |
Open loop current sensor using the Hall Effect Galvanic separation between primary and secondary Insulating plastic case recognized according to UL 94-V0 Supply voltage:+5V No insertion loss Small size Standards: IEC 60664-1:2020 IEC 61800-5-1:2022 IEC 62109-1:2010
more...
|
| AN3V 120 PB55 |
120 |
±300 |
5 |
2.5±2V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+5V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
more...
|
| AS1V 200 H00 |
200 |
±200 |
5 |
2.5±2V |
±1.0 |
50 |
-40~105 |
20.5x10.5 mm |
|
Molex 5045-04A |
- Open loop current sensor using the Hall Effect.
- Output voltage is proportional to the supply voltage
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- Supply voltage: +5V
- No insertion loss.
- Small size
- Standards: EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
more...
|
| AS1V 200 H01 |
200 |
±600 |
5 |
2.5±0.625V |
±1.0 |
50 |
-40~105 |
20.5x10.5 mm |
|
Molex 5045-04A |
- Open loop current sensor using the Hall Effect.
- Output voltage is proportional to the supply voltage
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- Supply voltage: +5V
- No insertion loss.
- Small size
- Standards: EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
more...
|
| AS1V 200 H07 |
200 |
±200 |
5 |
2.5±0.625V |
±1.0 |
50 |
-40~105 |
20.5x10.5 mm |
|
RVVP 3 x 0.3mm x 0.3mm -600 |
Open loop current sensor using the Hall Effect Galvanic separation between primary and secondary Insulating plastic case recognized according to UL 94-V0 Supply voltage:+5V No insertion loss Small size Standards: IEC 60664-1:2020 IEC 61800-5-1:2022 IEC 62109-1:2010
more...
|
| AS1V 300 H00 |
300 |
±300 |
5 |
2.5±2V |
±1.0 |
50 |
-40~105 |
20.5 x 10.5 mm |
|
MOLEX 5045-04A |
- Open loop current sensor using the Hall Effect.
- Output voltage is proportional to the supply voltage
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- Supply voltage: +5V
- No insertion loss.
- Small size
- Standards: EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
more...
|
| AS1V 300 H01 |
300 |
±900 |
5 |
2.5±0.625V |
±1.0 |
50 |
-40~105 |
20.5 x 10.5 mm |
|
MOLEX 5045-04A |
- Open loop current sensor using the Hall Effect.
- Output voltage is proportional to the supply voltage
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- Supply voltage: +5V
- No insertion loss.
- Small size
- Standards: EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
more...
|
| AS1V 400 H00 |
400 |
±400 |
5 |
2.5±2V |
±1.0 |
50 |
-40~105 |
20.5 x 10.5 mm |
|
MOLEX 5045-04A |
- Open loop current sensor using the Hall Effect.
- Output voltage is proportional to the supply voltage
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- Supply voltage: +5V
- No insertion loss.
- Small size
- Standards: EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
more...
|
| AS1V 400 H01 |
400 |
±900 |
5 |
2.5±0.625V |
±1.0 |
50 |
-40~105 |
20.5 x 10.5 mm |
|
MOLEX 5045-04A |
Open loop current sensor using the Hall Effect. - Output voltage is proportional to the supply voltage
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- Supply voltage: +5V
- No insertion loss.
- Small size
- Standards: EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
more...
|
| AS1V 500 H00 |
500 |
±500 |
5 |
2.5±2V |
±1.0 |
50 |
-40~105 |
20.5 x 10.5 mm |
|
MOLEX 5045-04A |
- Open loop current sensor using the Hall Effect.
- Output voltage is proportional to the supply voltage
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- Supply voltage: +5V
- No insertion loss.
- Small size
- Standards: EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
more...
|
| AS1V 500 H01 |
500 |
±900 |
5 |
2.5±0.625V |
±1.0 |
50 |
-40~105 |
20.5 x 10.5 mm |
|
MOLEX 5045-04A |
- Open loop current sensor using the Hall Effect.
- Output voltage is proportional to the supply voltage
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- Supply voltage: +5V
- No insertion loss.
- Small size
- Standards: EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
more...
|
| AS1V 600 H00 |
600 |
±600 |
5 |
2.5±2V |
±1.0 |
50 |
-40~105 |
20.5 x 10.5 mm |
|
MOLEX 5045-04A |
- Open loop current sensor using the Hall Effect.
- Output voltage is proportional to the supply voltage
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- Supply voltage: +5V
- No insertion loss.
- Small size
- Standards: EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
more...
|
| AS1V 600 H01 |
600 |
±900 |
5 |
2.5±0.625V |
±1.0 |
50 |
-40~105 |
20.5 x 10.5 mm |
|
MOLEX 5045-04A |
- Open loop current sensor using the Hall Effect.
- Output voltage is proportional to the supply voltage
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- Supply voltage: +5V
- No insertion loss.
- Small size
- Standards: EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
more...
|
| AS1V 700 H00 |
700 |
±700 |
5 |
2.5±2V |
±1.0 |
50 |
-40~105 |
20.5 x 10.5 mm |
|
MOLEX 5045-04A |
- Open loop current sensor using the Hall Effect.
- Output voltage is proportional to the supply voltage
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- Supply voltage: +5V
- No insertion loss.
- Small size
- Standards: EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
more...
|
| AS1V 800 H00 |
800 |
±800 |
5 |
2.5±2V |
±1.0 |
50 |
-40~105 |
20.5 x 10.5 mm |
|
MOLEX 5045-04A |
- Open loop current sensor using the Hall Effect.
- Output voltage is proportional to the supply voltage
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- Supply voltage: +5V
- No insertion loss.
- Small size
- Standards: EN50178: 1997, IEC 61010-1: 2000, UL 508: 2010
more...
|
| AN3V 10 PB31 |
10 |
±25 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
more...
|
| AN3V 10 PB51 |
10 |
±25 |
5 |
2.5±2V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+5V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
more...
|
| AN3V 16 PB30 |
16 |
±40 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
more...
|
| AN3V 16 PB31 |
16 |
±40 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
more...
|
| AN3V 16 PB51 |
16 |
±40 |
5 |
2.5±2V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+5V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
more...
|
| AN3V 20 PB30 |
20 |
±50 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
more...
|
| AN3V 20 PB31 |
20 |
±50 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
more...
|
| AN3V 20 PB51 |
20 |
±50 |
5 |
2.5±2V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+5V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
more...
|
| AN3V 32 PB30 |
32 |
±80 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
more...
|
| AN3V 32 PB31 |
32 |
±80 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
more...
|
| AN3V 32 PB51 |
32 |
±80 |
5 |
2.5±2V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+5V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
more...
|
| AN3V 40 PB30 |
40 |
±100 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
more...
|
| AN3V 40 PB31 |
40 |
±100 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
more...
|
| AN3V 40 PB51 |
40 |
±100 |
5 |
2.5±2V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+5V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
more...
|
| AN3V 50 PB31 |
50 |
±125 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
more...
|
| AN3V 50 PB51 |
50 |
±125 |
5 |
2.5±2V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+5V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
more...
|
| AN3V 80 PB35 |
80 |
±200 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
more...
|
| AN3V 80 PB31 |
80 |
±200 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
more...
|
| AN3V 80 PB51 |
80 |
±200 |
5 |
2.5±2V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+5V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
more...
|
| AN3V 100 PB35 |
100 |
±250 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
more...
|
| AN3V 100 PB31 |
100 |
±250 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
more...
|
| AN3V 100 PB51 |
100 |
±250 |
5 |
2.5±2V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+5V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
more...
|
| AN3V 120 PB35 |
120 |
±300 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
more...
|
| AN3V 120 PB31 |
120 |
±300 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
more...
|
| AN3V 120 PB51 |
120 |
±300 |
5 |
2.5±2V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+5V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
more...
|
| AN3V 150 PB55 |
150 |
±375 |
5 |
2.5±2V |
+1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- ASIC Technology.
- Maintain output proportional to changes in the power supply(include offset and sensitivity).
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Small size.
- Standards: IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
more...
|
| AN3V 180 PB55 |
180 |
±375 |
5 |
2.5±2V |
+1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- ASIC Technology.
- Maintain output proportional to changes in the power supply(include offset and sensitivity).
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Small size.
- Standards: IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
more...
|
| AN3V 200 PB55 |
200 |
±375 |
5 |
2.5±2V |
+1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- ASIC Technology.
- Maintain output proportional to changes in the power supply(include offset and sensitivity).
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Small size.
- Standards: IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
more...
|
| AN3V 150 PB35 |
150 |
±375 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
more...
|
| AN3V 180 PB35 |
180 |
±375 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
more...
|
| AN3V 200 PB35 |
200 |
±375 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
more...
|
| FR1C 300 H00 |
300 |
±400 |
13.5 |
CAN ID |
±60mA |
|
-40~85 |
Φ24.2 mm |
|
Tyco AMP 1473672-1 |
- Current sensor using Fluxgate technology for automotive use,BMS, SOC, SOH, SOF.
- Overcurrent detection mechanism
- Panel mounting
- Unipolar +12V battery power supply
- Output signal: High speed CAN (up to 500 kBps)
- Configurable internal digital low-pass frequency filter
- Configurable CAN speed/CAN ID
- UL508 compliant
- Ingress Protection - IP42 level.
more...
|
| FR1C 500 H00 |
500 |
±600 |
13.5 |
CAN ID |
±60mA |
|
-40~85 |
Φ24.2 mm |
|
Tyco AMP 1473672-1 |
- Current sensor using Fluxgate technology for automotive use,BMS, SOC, SOH, SOF.
- Overcurrent detection mechanism
- Panel mounting
- Unipolar +12V battery power supply
- Output signal: High speed CAN (up to 500 kBps)
- Configurable internal digital low-pass frequency filter
- Configurable CAN speed/CAN ID
- UL508 compliant
- Ingress Protection - IP42 level.
more...
|