| AN5V 30 PB00 |
30 |
±90 |
±12...15 |
±4V |
±1.0 |
50 |
-40~85 |
NA |
+ |
|
- 30A open loop current sensor using the Hall Effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion loss.
- Small size.
- Standards:
- EN50178: 1997
- IEC 61010-1: 2000
- UL 508: 2010
- Small size current sensors employed in solar inverters and battery management systems
more...
|
| AN5V 10 PB00 |
10 |
±30 |
±12...15 |
±4V |
±1.0 |
50 |
-40~85 |
NA |
+ |
|
- 10A open loop current sensor using the Hall Effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion loss.
- Small size.
- Standards:
- EN50178: 1997
- IEC 61010-1: 2000
- UL 508: 2010
- AC and DC currents sensor in automotive and industrial applications
more...
|
| AN3V 10 PB50 |
10 |
±25 |
5 |
2.5±2V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+5V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
- Very low power consumption open loop current sensors
more...
|
| AN5V 15 PB00 |
15 |
±45 |
±12...15 |
±4V |
±1.0 |
50 |
-40~85 |
NA |
+ |
|
- 15A open loop current sensor using the Hall Effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion loss.
- Small size.
- Standards:
- EN50178: 1997
- IEC 61010-1: 2000
- UL 508: 2010
- Easy to use and simpler design ASIC current sensor
more...
|
| AN3V 16 PB50 |
16 |
±40 |
5 |
2.5±2V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+5V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
- Supply voltage 5V Electrical Measuring Analog Module Small AC Current Transducer 10A 16A 20A 32A 40A 50A
more...
|
| AN5V 20 PB00 |
20 |
±60 |
±12...15 |
±4V |
±1.0 |
50 |
-40~85 |
NA |
+ |
|
- 20A open loop current sensor using the Hall Effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion loss.
- Small size.
- Standards:
- EN50178: 1997
- IEC 61010-1: 2000
- UL 508: 2010
- High-performance transducers for track motor control
more...
|
| AN3V 20 PB50 |
20 |
±50 |
5 |
2.5±2V |
±1 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+5V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
- ASIC current sensors for HVDC application area
more...
|
| AN5V 25 PB00 |
25 |
±75 |
±12...15 |
±4V |
±1 |
50 |
-40~85 |
NA |
+ |
|
- 25A open loop current sensor using the Hall Effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion loss.
- Small size.
- Standards:
- EN50178: 1997
- IEC 61010-1: 2000
- UL 508: 2010
- Low sensitivity error ASIC sensors
more...
|
| AN3V 32 PB50 |
32 |
±80 |
5 |
2.5±2V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+5V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
- Small size PCB mounting open loop current sensor
more...
|
| AN3V 40 PB50 |
40 |
±100 |
5 |
2.5±2V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+5V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
- Electronic components hall effect current sensor
more...
|
| AN5V 50 PB00 |
50 |
±150 |
±12...15 |
±4V |
±1.0 |
50 |
-40~85 |
NA |
+ |
|
- Open loop current sensor using the Hall Effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion loss.
- Small size.
- Standards:
- EN50178: 1997
- IEC 61010-1: 2000
- UL 508: 2010
- Hall effect sensor working principle and applications
more...
|
| AN1V 50 PB511 |
50 |
±50 |
5 |
2.5±2V |
±1.0 |
250 |
-40~150 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- ASIC Technology.
- Maintain output proportional to changes in the power supply(include offset and sensitivity).
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Small size.
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
- Hall effect sensors series current sensor manufactured by factory for battery management
more...
|
| AN1V 50 PB512 |
50 |
±50 |
5 |
2.5±2V |
±1.0 |
250 |
-40~150 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- ASIC Technology.
- Maintain output proportional to changes in the power supply(include offset and sensitivity).
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Small size.
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
- Current sensor for both AC and DC current detection DC-DC converter control
more...
|
| AN1V 50 PB501 |
50 |
50 |
5 |
0.55...4.55V |
±1.0 |
250 |
-40~150 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- ASIC Technology.
- Maintain output proportional to changes in the power supply(include offset and sensitivity).
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Small size.
- Standards: IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
- Current sensors for uninterruptible power supply
more...
|
| AN1V 50 PB502 |
50 |
50 |
5 |
0.55...4.55V |
±1.0 |
250 |
-40~150 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- ASIC Technology.
- Maintain output proportional to changes in the power supply(include offset and sensitivity).
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Small size.
- Standards: IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
- Current sensors designed for EV traction and auxiliary inverters, DC-DC converters, on-board chargers, solar inverters
more...
|
| AN1V 50 PB311 |
50 |
±50 |
3.3 |
1.65±1.32V |
±1.0 |
250 |
-40~150 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- ASIC Technology.
- Maintain output proportional to changes in the power supply(include offset and sensitivity).
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Small size.
- Standards: IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
- Small size open loop current sensor unidirectional power supply voltage 3.3V for PCB mounting
more...
|
| AN1V 50 PB312 |
50 |
±50 |
3.3 |
1.65±1.32V |
±1.0 |
250 |
-40~150 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- ASIC Technology.
- Maintain output proportional to changes in the power supply(include offset and sensitivity).
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Small size.
- Standards: IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
- High quality open loop current sensor with respect to applicable standards for wide applications in industry
more...
|
| AN3V 50 PB30 |
50 |
±125 |
3.3 |
1.65±1.15V |
+1.0 |
250 |
-40~150 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
- Hall effect current sensor for new energy industrial automation
more...
|
| AN3V 50 PB50 |
50 |
±125 |
5 |
2.5±2V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+5V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
- Supply voltage 5V current sensor for Servo Motor
more...
|
| AN3V 80 PB55 |
80 |
±200 |
5 |
2.5±2V |
+1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- ASIC Technology.
- Maintain output proportional to changes in the power supply(include offset and sensitivity).
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Small size.
- Standards: IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
- Current sensor for renewable energy systems
more...
|
| AN1V 100 PB511 |
100 |
±100 |
5 |
2.5±2V |
±1.0 |
250 |
-40~150 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- ASIC Technology.
- Maintain output proportional to changes in the power supply(include offset and sensitivity).
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Small size.
- Standards: IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
- Current sensors for various applications
more...
|
| AN1V 100 PB512 |
100 |
±100 |
5 |
2.5±2V |
±1.0 |
250 |
-40~150 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- ASIC Technology.
- Maintain output proportional to changes in the power supply(include offset and sensitivity).
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Small size.
- Standards: IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
- Durable high power DC/AC current sensor for industrial electronic devices
more...
|
| AN1V 100 PB501 |
100 |
100 |
5 |
0.55...4.55V |
±1.0 |
250 |
-40~150 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- ASIC Technology.
- Maintain output proportional to changes in the power supply(include offset and sensitivity).
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Small size.
- Standards: IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
- Industrial grade current sensor with high sensitivity real-time monitoring for hybrid electric vehicle
more...
|
| AN1V 100 PB502 |
100 |
100 |
5 |
0.55...4.55V |
±1.0 |
250 |
-40~150 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- ASIC Technology.
- Maintain output proportional to changes in the power supply(include offset and sensitivity).
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Small size.
- Standards: IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
- 50A-300A High precision current sensor for fast detection, current monitoring and protection
more...
|
| AN1V 100 PB311 |
100 |
±100 |
3.3 |
1.65±1.32V |
±1.0 |
250 |
-40~150 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- ASIC Technology.
- Maintain output proportional to changes in the power supply(include offset and sensitivity).
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Small size.
- Standards: IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
- 3.3V high sensitivity current sensor for PCB board mounting battery powered
more...
|
| AN1V 100 PB312 |
100 |
±100 |
3.3 |
1.65±1.32V |
±1.0 |
250 |
-40~150 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- ASIC Technology.
- Maintain output proportional to changes in the power supply(include offset and sensitivity).
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Small size.
- Standards: IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
- high frequency Supply voltage 3.3V open loop current sensor for AC variable speed
more...
|
| AN3V 100 PB55 |
100 |
±250 |
5 |
2.5±2V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+5V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
Hall effect current sensor supply voltage 5V high sensitivity low noise for combining manifolds for PCB board mounting Electronic Equipment
more...
|
| AN3V 120 PB55 |
120 |
±300 |
5 |
2.5±2V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+5V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
Current sensor detects and measures the electric current passing through a conductor. It turns the current into a quantifiable output, such as a voltage, current, or digital signal, which may be utilised in a variety of applications for monitoring, control, or protection.
more...
|
| AN1V 150 PB511 |
150 |
±150 |
5 |
2.5±2V |
±1.0 |
250 |
-40~125 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- ASIC Technology.
- Maintain output proportional to changes in the power supply(include offset and sensitivity).
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Small size.
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
more...
|
| AN1V 150 PB512 |
150 |
±150 |
5 |
2.5±2V |
±1.0 |
250 |
-40~125 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- ASIC Technology.
- Maintain output proportional to changes in the power supply(include offset and sensitivity).
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Small size.
- Standards: IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Current sensors are frequently used to measure and control the load current in power supplies, safety circuits and a variety of control circuits. In applications where controlling the current is required, such as in power supplies, accurately sensing the magnitude of the current is a fundamental requirement.
more...
|
| AN1V 150 PB502 |
150 |
150 |
5 |
0.55...4.55V |
±1.0 |
250 |
-40~125 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- ASIC Technology.
- Maintain output proportional to changes in the power supply(include offset and sensitivity).
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Small size.
- Standards: IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Hall Effect current sensors are devices that utilize the Hall Effect principle to measure current, providing high accuracy and isolation in various applications.
more...
|
| AN1V 150 PB311 |
150 |
±150 |
3.3 |
1.65±1.32V |
±1.0 |
250 |
-40~125 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- ASIC Technology.
- Maintain output proportional to changes in the power supply(include offset and sensitivity).
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Small size.
- Standards: IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Current transducers are widely used across industrial, automotive, energy, and renewable sectors for accurate current measurement, monitoring, and control to ensure safety, efficiency, and system reliability
more...
|
| AN1V 150 PB312 |
150 |
±150 |
3.3 |
1.65+1.32V |
±1.0 |
250 |
-40~125 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- ASIC Technology.
- Maintain output proportional to changes in the power supply(include offset and sensitivity).
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Small size.
- Standards: IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Current transducers are crucial in industrial automation and motor control systems. They monitor electric motor currents, providing feedback to control systems to regulate speed and torque accurately. Additionally, in manufacturing, transducers enable load balancing, fault detection, and predictive maintenance in motors, generators, and coupled machinery
more...
|
| AN1V 200 PB511 |
200 |
±200 |
5 |
2.5±2V |
±1.0 |
250 |
-40~85 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- ASIC Technology.
- Maintain output proportional to changes in the power supply(include offset and sensitivity).
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Small size.
- Standards: IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
200A High Sensitivity Real-time Monitoring for Hybrid Electric Vehicle, Powertrain, Automotive Electronics and Circuit Detection
more...
|
| AN1V 200 PB512 |
200 |
±200 |
5 |
2.5±2V |
±1.0 |
250 |
-40~85 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- ASIC Technology.
- Maintain output proportional to changes in the power supply(include offset and sensitivity).
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Small size.
- Standards: IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Small size Low Noise for Motor Control,battery management, IoT Devices and Industrial Electronic Equipment
more...
|
| AN1V 200 PB501 |
200 |
200 |
5 |
0.55...4.55V |
±1.0 |
250 |
-40~85 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- ASIC Technology.
- Maintain output proportional to changes in the power supply(include offset and sensitivity).
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Small size.
- Standards: IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
High frequency high reliability current sensor affordable hall effect current sensor integrated current sensor for smart electronic systems and fast detection
more...
|
| AN1V 200 PB502 |
200 |
0-200 |
5 |
0.55+4V |
±1.0 |
250 |
-40~85 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- ASIC Technology.
- Maintain output proportional to changes in the power supply(include offset and sensitivity).
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Small size.
- Standards: IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
50A 100A 150A 200A 250A 300A Current sensor for current monitoring and protection
more...
|
| AN1V 200 PB311 |
200 |
±200 |
3.3 |
1.65±1.32V |
±1.0 |
250 |
-40~85 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- ASIC Technology.
- Maintain output proportional to changes in the power supply(include offset and sensitivity).
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Small size.
- Standards: IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Open loop 200A current sensor using the Hall effect supply voltage 3.3V wide measurement 50A 100A 150A 200A 250A 300A AC DC Current Monitoring Sensor for PCB mouting
more...
|
| AN1V 200 PB312 |
200 |
±200 |
3.3 |
1.65±1.32V |
±1.0 |
250 |
-40~85 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- ASIC Technology.
- Maintain output proportional to changes in the power supply(include offset and sensitivity).
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Small size.
- Standards: IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Multifunctional, high-linearity, high-precision,high temperature resistant current sensor for for motor control ,home appliance, robotics,laboratory,industrial automation
more...
|
| AN3V 10 PB31 |
10 |
±25 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
HLSR current transducer in power electronics, motor drives, and renewable energy systems.
more...
|
| AN3V 10 PB51 |
10 |
±25 |
5 |
2.5±2V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+5V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
SMD PCB mount current sensor for industrial
more...
|
| AN3V 16 PB30 |
16 |
±40 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
Professional hall effect current sensor manufacturer for fast switching applications
more...
|
| AN3V 16 PB31 |
16 |
±40 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
Small size renewable energy current transducer 10A-120A for high efficiency SMPS
more...
|
| AN3V 16 PB51 |
16 |
±40 |
5 |
2.5±2V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+5V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
Industrial current transducer alternative supplier current transducer for VFD systems
more...
|
| AN3V 20 PB30 |
20 |
±50 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
Cost effective Hall effect current sensor for AI server PSU
more...
|
| AN3V 20 PB31 |
20 |
±50 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
Current Sensor 20A 3.3V 2.5us PCB HLSR-P
more...
|
| AN3V 20 PB51 |
20 |
±50 |
5 |
2.5±2V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+5V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
HLSR Industrial Current Sensors
more...
|
| AN3V 32 PB30 |
32 |
±80 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
The different types of available current sensors and their typical use cases
more...
|
| AN3V 32 PB31 |
32 |
±80 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
Current sensor selection guide for motor control applications and how to test current sensor
more...
|
| AN3V 32 PB51 |
32 |
±80 |
5 |
2.5±2V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+5V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
Hall effect sensor ensure for battery efficiency and protecting against current overloads
more...
|
| AN3V 40 PB30 |
40 |
±100 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
How to replace a hall effect transducer for current measurement
more...
|
| AN3V 40 PB31 |
40 |
±100 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
Small size open cloop supply voltage 3.3V linearity ±0.5 for 250khz for industrial applications
more...
|
| AN3V 40 PB51 |
40 |
±100 |
5 |
2.5±2V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+5V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
Electronic components PCB board mounting open cloop hall current sensor for SMPS and UPS
more...
|
| AN3V 50 PB31 |
50 |
±125 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
Supply voltage+3.3V open loop current sensor based on Hall effect PCB installation
more...
|
| AN3V 50 PB51 |
50 |
±125 |
5 |
2.5±2V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+5V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
Good Iinear variable differential current sensor active speed sensor wide measure range10A 16A 20A 32A 40A 50A 80A 100A 120A
more...
|
| AN3V 80 PB35 |
80 |
±200 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
How integrated current sensors can open new perspectives for system
more...
|
| AN3V 80 PB31 |
80 |
±200 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
UPS power HLSR current sensor price
more...
|
| AN3V 80 PB51 |
80 |
±200 |
5 |
2.5±2V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+5V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
Small size height 8.7mm open loop 250kHz bandwidth supply voltage+5V for MPPT
more...
|
| AN3V 100 PB35 |
100 |
±250 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
Supply voltage 3.3V hall effect current sensor for combining manifolds
more...
|
| AN3V 100 PB31 |
100 |
±250 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
High precision magnetic sensor interfacing ASIC
more...
|
| AN3V 100 PB51 |
100 |
±250 |
5 |
2.5±2V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+5V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
How integrated current sensors can open new perspectives for system design.
more...
|
| AN3V 120 PB35 |
120 |
±300 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
Hall current sensor 80-200A AC/DC Input/output suitable for industrial power supply with an aperture of ±0.3 mm
more...
|
| AN3V 120 PB31 |
120 |
±300 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
Hall current sensor 3.3V AC/DC 10A 16A 20A 32A 40A 50A 80A 100A 120A electrical Current Transducer analog output
more...
|
| AN3V 120 PB51 |
120 |
±300 |
5 |
2.5±2V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+5V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
Current transducer sensor 120A range 80mV/A sensitivity PCB mount for motor drives UPS
more...
|
| AN1V 300 PB501 |
300 |
±300 |
5 |
0.55-4.55V |
±1.0 |
250 |
-40~85 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- ASIC Technology.
- Maintain output proportional to changes in the power supply(include offset and sensitivity).
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Small size.
- Standards: IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
New original Hall sensor available in stock replace ACS758 current sensor
more...
|
| AN1V 300 PB502 |
300 |
±300 |
5 |
0.55-4.55V |
±1.0 |
250 |
-40~85 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- ASIC Technology.
- Maintain output proportional to changes in the power supply(include offset and sensitivity).
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Small size.
- Standards: IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Bidirectional AC/DC +/-300 amp isolated current sensor module ACS758 +/-300A
more...
|
| AN3V 150 PB55 |
150 |
±375 |
5 |
2.5±2V |
+1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- ASIC Technology.
- Maintain output proportional to changes in the power supply(include offset and sensitivity).
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Small size.
- Standards: IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Primary current direction marking diagram open loop bidirectional current sensor for general power electronics
more...
|
| AN3V 180 PB55 |
180 |
±375 |
5 |
2.5±2V |
+1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- ASIC Technology.
- Maintain output proportional to changes in the power supply(include offset and sensitivity).
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Small size.
- Standards: IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Customized current automotive grade current sensor for circuit breaker
more...
|
| AN3V 200 PB55 |
200 |
±375 |
5 |
2.5±2V |
+1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- ASIC Technology.
- Maintain output proportional to changes in the power supply(include offset and sensitivity).
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Small size.
- Standards: IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
Open loop current sensor transducer 200A
more...
|
| AN3V 150 PB35 |
150 |
±375 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
Industrial combining manifold current measurement hall sensor alternative to LA17P S05 open loop current transducer for industrial converters
more...
|
| AN3V 180 PB35 |
180 |
±375 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
250kHz bandwidth 2.5µs fast response time current transducer alternative HLSR
more...
|
| AN3V 200 PB35 |
200 |
±375 |
3.3 |
1.65±1.15V |
±1.0 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall effect.
- Galvanic separation between primary and secondary.
- Insulating plastic case recognized according to UL 94-V0.
- No insertion losses.
- Supply voltage:+3.3V
- Small size.
- h=8.7mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
200A Ultra thin HLSR 8.7mm height galvanic isolated current detector -40 to 105℃ wide temperature
more...
|
| AN5V 60 PB00 |
60 |
±180 |
±12...15 |
±4V |
±1 |
50 |
-40~85 |
NA |
+ |
|
- 60A open loop current sensor using the Hall Effect
- Supply voltage ±12...±15V
- Galvanic insulation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion loss
- Small size
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
more...
|
| AN6V 20 PB50 |
20 |
±50 |
5 |
±2V |
±0.8 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall Effect
- Galvanic insulation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion loss
- Supply voltage: +5V
- Height h=10.15mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
more...
|
| AN6V 32 PB50 |
32 |
±80 |
5 |
±2V |
±0.8 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall Effect
- Galvanic insulation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion loss
- Supply voltage: +5V
- Height h=10.15mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
more...
|
| AN6V 40 PB50 |
40 |
±100 |
5 |
±2V |
±0.8 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall Effect
- Galvanic insulation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion loss
- Supply voltage: +5V
- Height h=10.15mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010
more...
|
| AN6V 50 PB50 |
50 |
±125 |
5 |
±2V |
±0.8 |
250 |
-40~105 |
NA |
+ |
|
- Open loop current sensor using the Hall Effect
- Galvanic insulation between primary and secondary
- Insulating plastic case recognized according to UL 94-V0
- No insertion loss
- Supply voltage: +5V
- Height h=10.15mm
- Standards:
- IEC 60664-1:2020
- IEC 61800-5-1:2022
- IEC 62109-1:2010